170
CONTROL CVs
CV234
Smoke Unit Fan Rev Speed
Description
This Value Sets the Smoke Units Fan Speed For Each Rev
Values
0-32
Initial Value
2
Related CVs
Bit 7
Bit 0
0 0 0 0 0 0 1 0
The smoke unit’s fan speed varies from the idle speed (CV235) with
each rev level increase. Fan speed is calculated as:
CV235 – (Rev * CV234)
Increasing this value results in the smoke pushing up higher at each
increased rev, but thinner.