![Broadcom G610 Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/broadcom/g610/g610_hardware-installation-manual_2815739039.webp)
53-1004408-11 Installation Guide
Brocade
®
G610 Switch Hardware Installation Guide
Initial Setup and Verification
Items Required
The following items are required for initial setup and verification of the device:
•
The device is mounted and connected to a power source, with the required power supply, fan assemblies,
transceivers, and cables installed.
•
A workstation computer with a terminal emulator application installed, such as PuTTY, XShell, or SecureCRT on
Windows.
•
An unused IP address with a corresponding subnet mask and gateway address.
•
A serial cable with an RJ-45 connector.
•
An Ethernet cable.
•
Access to an FTP server or USB device for uploading (backing up) or downloading the device configuration (optional).
NOTE
Obtain a USB drive certified by Broadcom:
•
SANDisk 32 CZ48 USB 3.0 Flash Drive (SDCZ48-032G-UAM46)
•
SANDisk 16 CZ48 USB 3.0 Flash Drive (SDCZ48-016G-UAM46)
•
PNY Attache 3.0 4 USB 32GB Flash Drive
•
PNY Attache 3.0 4 USB 16GB Flash Drive
These drives are not orderable from Broadcom but are generically-branded and can be purchased from other
suppliers.
Providing Power to the Device
Perform the following steps to provide power to the device.
1. Connect the power cord to the power supply, and then to the power source. Ensure that the power cord has a
minimum service loop of 6 in. available and routed to avoid stress.
The system power supply LED displays amber until power-on self-test (POST) is complete, and then changes to
green. The switch usually requires several minutes to boot and complete the POST.
2. After POST is complete, verify that the switch power and switch status LEDs are green.
For more information about how to interpret POST, boot, and diagnostics tests, see
.
Establishing a First-Time Serial Connection
Perform the following steps to log on to the device through a serial connection.
1. Connect the device with the workstation.
•
For SKU Wedge, connect the serial cable to the serial port on the device and to an RS-232 serial port on the
workstation.
•
For SKU Wedge2, connect the mini USB of the console cable to the device and the RJ-45 of the cable to the
RJ-232 serial port on the workstation.
If the serial port on the workstation is RJ-45 instead of RS-232, remove the adapter on the end of the serial cable and
insert the exposed RJ-45 connector into the RJ-45 serial port on the workstation.
53-1004408-11