53-1004105-13 Hardware Installation Guide
Brocade X6-8 Director
Hardware Installation Guide
Chassis Factory Serial Num: BAF0289K00H
errDump and errShow
Use the
errShow
command to display device error log messages one at a time. Use the
errDump
command to display
error log messages without any page breaks. The output of these commands are unique for each Control Processor (CP),
so must be executed on each CP blade to obtain a complete record.
Following is a partial example of
errDump
output.
chassisX6:admin> errdump
2016/03/28-08:44:28,[FV-1001], 90, SLOT 1 CHASSIS,INFO,My_Switch,Flow Vision daemon initialized.
2016/03/28-08:44:51,[FSSM-1002],91,SLOT 1 CHASSIS,INFO,My_Chassis,HA State is in sync.
2016/03/28-08:44:51,[SULB-1003],92,SLOT 1 CHASSIS,INFO,My_Chassis,Firmwarecommit has started.
2016/03/28-08:48:27,[SULB-1004],93,SLOT 1 CHASSIS,INFO,My_Chassis,Firmwarecommit has completed.
2016/03/28-08:48:27,[SULB-1036],94,SLOT 1 CHASSIS,INFO,My_Chassis,The new Version: Fabric OS v8.0.1_bld52.
2016/03/28-08:48:27,[SULB-1002],95,SLOT 1 CHASSIS,INFO,My_Chassis,Firmwaredownload command has completed
successfully.
2016/03/28-08:50:51,[IPAD-1003],96,SLOT 1 CHASSIS,INFO,My_Chassis,DNS parameters saved successfully.
------------------------------------------------------------------------------------------------------------
The output can contain several thousand lines. Use the
errClear
command to reset the output when needed. This
command clears all error log messages for all director instances on the CP where the command is issued.
Note the following about this output:
•
My_Switch
corresponds to what is entered for switchname and is a switch or logical switch event.
•
My_Chassis
corresponds to what is entered for chassisname and is a chassis event.
fanShow
Use the
fanShow
command to display the current status and speed of each installed fan.
The following example displays output from this command.
chassisX6-8:admin> fanshow
Fan 1 is Ok, speed is 7518 RPM
Fan 2 is Ok, speed is 7471 RPM
Fan 3 is Ok, speed is 7434 RPM
haShow
Use the
haShow
command to display the control processor (CP) status. The display includes the following information:
53-1004105-13