A.3 SCI Error – No Communication to Sensor
Figure 46: SCI Error
In principle, this message can have multiple reasons. Most likely, the USB cable was plugged into the openSDA (see
) instead of the KL46Z USB port. Another reason can be that the device software is corrupted and must be flashed
again (see
Section A.2, Different Versions of Explorer and Controller Board
). Because this error indicates a serial
communication issue, it is also possible that your sensor is defective or the USB cable might need to be replaced.
A.4 Xtalk Calibration – 3D Plot Is Not Visible
Figure 47: Xtalk Calibration
If there is an empty amplitude chart, it might be that the check box for
Hide binned pixels in plots
is still enabled. To see
low amplitudes while performing the Xtalk calibration make sure this option is not selected.
A.5 Xtalk Calibration – Amplitude Error
Figure 48: Amplitude Error Message