Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
-u Encoded Hot Plug Power Value 1 & 2 For NIC
-d Encoded Hot Plug Power Value 3 & 4 For NIC
-r Encoded Hot Plug Power Value 5 & 6 For NIC
-q Encoded Hot Plug Power Value 7 & 8 For NIC
-h Hot Plug Power For NIC - Enable
-a ASF/IPMI SMB Address for Pri. Port
-b IPMI SMB Address for Sec. Port
-c Cable Sense - Enable
-x GPIO 0 Config 0:Input 1:OutputH 2: OutputL (5714LOM and 5715 LOM only)
-y GPIO 2 Config 0:Input 1:OutputH 2: OutputL (5714LOM and 5715 LOM only)
-f L1ASPM_Debounce_En 0:Dis 1:En (PCIE Mobile devices only)
10.43 setipmi
cmd:
setipmi
Description:
Enable/Disable IPMI
Syntax:
setipmi
Options:
-d
Disable IPMI
-e
Enable IPMI
10.44 loadfw
cmd:
loadfw
Description:
Load Firmware to Tx/RX CPUs
Syntax:
loadfw
Options:
-b<HEX>
set breakpoint (0=off) (def=00000000)
-d<HEX>
data pattern to be used for memory init. (def=00000000)
page 72
Broadcom Confidential and Proprietary