![Broadcom 5720ZG Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/broadcom/5720zg/5720zg_user-manual_2815598080.webp)
Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
10.41 secfg4
cmd:
secfg4
Description:
Configure NVRAM Group 4
Syntax:
secfg4
Options:
-v Read VPD Vendor Data V0
-w Read/Write VPD Vendor Data V1
-n Reversed Nway 0:No 1:Yes
-s Limit WOL Speed to 10 0:No 1:Yes
-f Fiber WOL Capable 0:No 1:Yes
-c Clock-Run 0:Disable 1:Enable
-p Enable Phy Auto Power Down 0:No 1:Yes
-d Disable Power Saving 0:No 1:Yes
-h Hide MBA Setup Prompt 0:Disable 1:Enable
-k MBA Setup Hot Key 0:Ctrl-S 1:Ctrl-B
-i Capacitive Coupling 0:Disable 1:Enable
10.42 secfg5
cmd:
secfg5
Description:
Configure NVRAM Group 5
Syntax:
secfg5
Options:
-i Capacitive Coupling 0:Dis 1:En
-e SERDES Tx Drvr Pre-Emp - Primary
-t SERDES Tx Drvr Pre-Emp - Secondary
-z SERDES Tx Drvr Pre-Emp - ENABLE
page 71
Broadcom Confidential and Proprietary