background image

Installation and Operation Manual

Due to the dynamic nature of product design, the information contained in this 
document is subject to change without notice. Broadcast Tools, Inc., assumes no
responsibility for errors and/or omissions contained in this document. Revisions 
of this information or new editions may be issued to incorporate such changes.

Broadcast Tools® is a registered trademark of Broadcast Tools, Inc.

Copyright, 1989 - 2005 by Broadcast Tools, Inc. All rights reserved.

No part of this document may be reproduced or distributed without permission.

Visit 

www.broadcasttools.com

for important product update information.

Firmware Version 1.28 or above

Manual update 08-09-2004

SS 16.4

Sixteen Input, Quad Output Stereo Audio Matrix Switcher

INC

®

Содержание SS 16.4

Страница 1: ...his information or new editions may be issued to incorporate such changes Broadcast Tools is a registered trademarkof Broadcast Tools Inc Copyright 1989 2005 by Broadcast Tools Inc All rights reserved...

Страница 2: ...tion Guidelines 9 Inspection 9 Setting Operation Dip Switches 9 Power Up Feature 9 Macro Feature 9 Mounting 10 Power Supply Connection 10 Connecting Inputs Outputs Relays 10 Adjusting Input and Output...

Страница 3: ...d result in a hazardous condition WHO TO CONTACT FOR HELP If you have any questions regarding your product or you need assistance please con tact your distributor from whom you purchased this equipmen...

Страница 4: ...ls Each is equipped with front panel ACT LED indicators adjustable alarm delay and restore duration Sensitivity is factory set at 34db Front panel input selection switches are provided for each input...

Страница 5: ...annels may be programmed for the following operations Overlap Overlap one audio source with another while the button for the sec ond source is held down Both channels will be fed to the output until t...

Страница 6: ...ACT LED will illuminate and seri al ACT status is sent The ACT may be programmed for Number of seconds of silence that must be present before an alarm state is reached Number of seconds of audio prese...

Страница 7: ...d except for those few commands of variable length if the maximum length is not sent If acknowledgements are enabled successful commands are responded to with RRR while errors get an EEE response The...

Страница 8: ...D DIP Switches SW24 1 SW24 2 ID OFF OFF ID 0 ON OFF ID 1 OFF ON ID 2 ON ON ID 3 Baud Rate DIP Switches SW24 3 SW24 4 Baud Rate OFF OFF 9600 ON OFF 2400 OFF ON 19200 ON ON 38400 Audio Switching Mode DI...

Страница 9: ...macro button along with the desired input channel button To recall the macro press the macro button and any one of the desired stored macro s using the input channel buttons WEBSITE Visit our web site...

Страница 10: ...or to the output and ground for unbalanced output operation It is recommended that all cables connected to the SS 16 4 be looped through ferrite cores to suppress RF Surge protection with RF filterin...

Страница 11: ...32 inputs with the first unit providing the main output Remote Control Most front panel functions of the SS 16 4 may be remote controlled via removable screw terminals located on the rear panel The S...

Страница 12: ...cted to Output 4 16 Green State of Connection On if connected Power Status 1 Green Valid Power On Lock Active 1 Green Front panel locked On if locked Macro 1 Green Macro selection On if active PIP Act...

Страница 13: ...e package Windows 95 98 ME NT 2000 XP HyperTerminal etc using the protocol of 9600 N 8 1 Set the mode to DIRECT Flow Control to NONE and emulation to ANSI Connecting Two SS 16 4 s to a Single Computer...

Страница 14: ...d then MM The menu mode displays certain parameters and allows the set ting of these parameters In both cases device ID address 0 3 is specified with the on board dipswitches Type 0MM follow the promp...

Страница 15: ...ted Character String Meaning Allowable Values u Unit ID 0 3 ii Input Number 01 16 o Output Number 1 2 3 4 or Output Relay 1 8 oo Open Collectors 01 16 Set up Commands uC4x Set RS 232 RS 485 mode timin...

Страница 16: ...to any output open collector 3 will be turned on set to ground state This command is saved across power off uCFOn Turn off the effects of uCFOy open collectors behave according to DIP Switch 8 uCFRy S...

Страница 17: ...utput 4 OFF without affecting any other audio status uiiMA Mute input ii for all outputs uiiMo Mute input ii for output o uMo Mute output o uMA Mute all outputs Information Retrieval Commands POLL Res...

Страница 18: ...from 100msec to 9 9 seconds The default pulse length is one second Refer to page 16 for special Relay Open collector commands Each relay may be commanded to Latch On Turns on and stays on through powe...

Страница 19: ...R 1 Op R 1 F Op L 2 Op L 2 Chs Gnd Op R 2 Op R 2 G Op L 3 Op L 3 Chs Gnd Op R 3 Op R 3 H Op L 4 Op L 4 Chs Gnd Op R 4 Op R 4 I Mono1 Mono1 Ghs Gnd Mono2 Mono2 J Mono3 Mono3 Ghs Gnd Mono4 Mono4 K Ex In...

Страница 20: ...analog switch arrays Logic Microprocessor Non volatile memory Operation Control Front Panel Momentary switches Remote 24 Momentary closures to ground 40ms RS 232 RS 485 Multi drop Serial 2400 9600 19...

Страница 21: ...TI IE ES S O OR R R RE EM ME ED DI IE ES S TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LI...

Отзывы: