Field #07: RDS / SCA Auxiliary Modulation Level
AUX 2.0kHz -31.2dB
#########O
|
This field shows the actual modulation for an auxiliary SCA or RDS signal in dB referenced to 7.5kHz
or 10% of max peak modulation. The usual level for SCA signal is 0dB (7.5kHz) while standard RDS
modulation needs to be set at -11.5dB (2kHz)
•
Field #09: Internal Voltages
Vs2
Vs+
Vs-
+27.5V +12.5 -12.4
This field shows the internal regulated power supply voltages. The Vs+ and Vs- voltages on the GTX
& GRX models will typically o12.5 ±0.3V and -12.4V (+1/-2V).
The Vs2 battery voltage usually reads Vbat= +27.4 ± 0.4V, when the battery is completely charged
and AC mains are on. In case of battery operation, the equipment works satisfactory at any level the
range of 22 to 28V.
•
Field #10: Temperature, Data and Clock
T(A/H) +30°C n.a.
01 Jan 21 23:51:35
This field shows the equipment’s internal temperature in Celsius (°C). The ambient temperature
sensor is placed just behind the front panel and it may read higher than the ambient temperature. At
full output power and the maximum allowed ambient temperature of +45 °C, the internal
temperature could read up to 5 - 6 °C higher. The field software supports heatsink temperature
reading (Th) which is not measured on this equipment. There is no Temperature management, only
an alarm. Therefore the user is advised not to exceed temperature limits.
Bear in mind that the higher the ambient temperature, the lower the MTBF. As rule of thumb the life
is halved each 10 °C the temperature is increased. Assuming 10 year operating life at +25°C, which is
not unrealistic, it may become 2.5 years at +45°C.