background image

© 2019 Brivo Systems LLC. All rights reserved. 

 

P-MAN-PUB-ACS6000 Installation Manual 

 

BRIVO ACS6000 

INSTALLATION MANUAL 

 

 

 

Содержание ACS6000

Страница 1: ... 2019 Brivo Systems LLC All rights reserved P MAN PUB ACS6000 Installation Manual 1 BRIVO ACS6000 INSTALLATION MANUAL ...

Страница 2: ...lt the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation of the device FCC RF Radiation Exposure Statement 1 This transmitter mus...

Страница 3: ... with the written permission of Brivo Systems LLC The information contained within this document or within the product itself is considered the exclusive property of Brivo Systems LLC All information in this document or within the hardware and software product themselves is protected by the copyright and or other intellectual property laws of the United States Product Support All support for this ...

Страница 4: ...s reserved P MAN PUB ACS6000 Installation Manual 4 Table of Contents INTRODUCTION 5 PRE INSTALLATION PROCEDURES 7 GENERAL ASSEMBLY PROCEDURES 13 INSTALLATION PROCEDURES 22 POWERING AND TESTING PROCEDURES 38 CONFIGURATION PROCEDURES 40 ...

Страница 5: ...is for a control panel The control chassis contains the MAIN BOARD POWER SUPPLY BOARD PSB and may also contain one expansion board either a DOOR BOARD or an INPUT OUTPUT BOARD if using a standard chassis or three expansion boards in any combination of DOOR BOARDs or INPUT OUTPUT BOARDs if using a large chassis Expansion chassis Additional chassis containing POWER SUPPLY BOARD and one or two expans...

Страница 6: ...es Yes 1500 ft Transformer Block 6300FE 18 Yes Yes 100 ft Molex Connector N A 22 Yes No 1 ft Earth ground N A 6 Yes Yes 20 to 40 ft Reader Option 1 22 AWG 5504FE 22 Yes Yes 250 ft Reader Option 2 20 AWG 5400FE 20 Yes Yes 300 ft Reader Option 3 18 AWG 6300FE 18 Yes Yes 500 ft Additional Resources The following additional resources are available for the installer as well as the client Panel Networki...

Страница 7: ...ndby power Batteries should be connected in parallel Understand Brivo ACS6000 control panel product compatibility The ACS6000 control panel is compatible with a large number of standard reader models including the following UL tested for compatibility reader models HID600 Identiv 8110 HID RPK40 Allegion MTK15 AWID KP 6840 and OSDP reader 921PTPTEK00385 Brivo products are designed to accommodate th...

Страница 8: ... should contain the following parts a 1 metal chassis Packed inside the chassis are o An identify label to be adhered to the inside of the door o 1 cardboard box containing the MAIN BOARD and main board accessories o 1 MAIN BOARD o 1 anti static bubble wrap bag o 1 MAIN BOARD Accessory Kit 1 zipper bag 2 metal oxide varistors 16 2k W 5 resistors 5 ACS6000 style standoffs 5 ACS5000 style standoffs ...

Страница 9: ...TPUT BOARD B ACS6000 IO Kit There may be up to 15 of these kits and each should contain the following parts a 1 INPUT OUTPUT BOARD b 1 anti static bubble wrap bag c 1 INPUT OUTPUT BOARD Accessory Kit 1 zipper bag 2 metal oxide varistors 16 2k W resistors 5 standoffs for the INPUT OUTPUT BOARD 1 4P power wire harness d 1 identity label 4 If additional expansion chassis have been ordered with the co...

Страница 10: ...door This means that each DOOR BOARD can be used to control two doors The same inputs and outputs that drive a door can also be used for other devices In other words DOOR BOARDs do not need to be used to control doors WARNING Door Wiring If a node is to be used for a door do not connect any other device to the following terminal blocks REX DOOR DOOR LOCK RELAY and READER An INPUT OUTPUT BOARD cann...

Страница 11: ...s are based on the following restrictions a The control chassis containing the MAIN BOARD and the first expansion chassis can be up to 1500 feet apart b Each time another expansion chassis is added the maximum distance between the first and last chassis decreases by 50 feet So if there are three chassis in a system the control chassis plus two expansion chassis the two most distant chassis can be ...

Страница 12: ...ODE UNLESS PERMITTED BY THE LOCAL AUTHORITY HAVING JURISDICTION Doing so may cause interference with the operation of panic hardware WARNING Heat and Noise DO NOT INSTALL THE CONTROL PANEL IN AN AREA THAT COULD DROP BELOW 32 DEGRESS FAHRENHEIT OR EXCEED 120 DEGREES FAHRENHEIT Doing so can cause damage to components within the control panel DO NOT INSTALL THE CONTROL PANEL NEAR OR ON THE SAME CIRCU...

Страница 13: ...ight spaces the removable hinge design of the ACS6000 ACS6008 enclosures allow an installer to completely remove the chassis door and replace it just as easily upon completion of the installation 4 Remove any knock outs that may be required to accommodate conduit or wiring WARNING Knockouts DO NOT ATTEMPT TO REMOVE THE KNOCKOUTS WITH A HAMMER Banging on the knockouts may result in shock to the cir...

Страница 14: ...will note that the control panel kit contained an adhesive Identity Label This label should be affixed to the inside of the front door of the control chassis beneath the large wiring guide 6 Verify presence of optical tamper reflector on the inside of the chassis door 7 OPTIONAL Install the physical tamper switch in the chassis a Install the tamper switch in the chassis by removing the hex collar ...

Страница 15: ...Installation Manual 2019 Brivo Systems LLC All rights reserved P MAN PUB ACS6000 Installation Manual 15 Switch SW 7 setting description Figure 1 ACS6000 SW 7 Switch Bank Location Figure 2 ACS6000 SW 7 Switch Settings ...

Страница 16: ...wer off MAIN BOARD Place SW 7 6 dip switch in the ON position Power on the board and wait until you hear two two second long beeps and see the main heartbeat LED turn off Within 10 seconds of hearing the beeps place SW 7 6 dip switch back into the OFF position You will hear a one second long beep and the main heartbeat LED will start blinking again indicating the system is performing a factory res...

Страница 17: ...BOARD in the control chassis connect that to the power supply board Figure 4 Connect Expansion Board to Power Supply 3 If there are expansion chassis connect each DOOR BOARD and INPUT OUTPUT BOARD to the power supply board in each chassis a Use the power cable that came with each circuit board kit b The Power connector uses a PC style 4 wire molded Molex connector to deliver 12V Ground Power Detec...

Страница 18: ...ROL SYSTEM TO POWER ELECTRONIC STRIKES AND LATCHES The ACS6000 control panel Tamper On Off Toggle in the off position deactivates both optical and physical tamper switches Figure 5 Tamper Switch and Optical Tamper Sensor Locations NOTE If the technician is installing the ACS6000 MAIN BOARD as a retrofit in an ACS5000 enclosure there is no optical reflector present The optical tamper will not funct...

Страница 19: ...nsion board 2 Connect the tamper switch to one expansion board DOOR BOARD or INPUT OUTPUT BOARD in each expansion chassis Figure 7 Connect Tamper Switch to Expansion Board NOTE If a chassis has two boards connect the tamper switch to the upper board NOTE If the tamper switch is not going to be used leave the supplied jumper on this connector to keep the circuit closed Connect the battery leads to ...

Страница 20: ... each circuit board kit to the power supply BATTERY INPUT terminal block a Connect the black wire to the ground GND terminal b Connect the red wire to the 12V terminal c Make sure the battery wires are segregated at least inch away from all other input output wiring NOTE Power Standby Level 1 for UL listed systems Figure 8 Connect Battery Leads to Power Supply ...

Страница 21: ...ion is needed use 18 AWG wire minimum grade to connect to the 16VAC 19VDC POWER INPUT terminal block on the power supply board using terminals DC AC1 and DC AC2 Figure 9 Connect AC Transformer to Power Supply 2 To maintain UL compliance the unit must be powered by a UL 294 Listed power supply capable of supplying 16VAC 19VDC 2 1A to the power supply board Model Circuit Voltage VDC AC Current mA A ...

Страница 22: ...nnecting an ACS6000 mainboard to a door IO board use the smaller connector at one end of the cable for the mainboard and the first middle larger connector for the door IO board If connecting two door IO boards use the first and second larger board connectors In an ACS6008 enclosure you have the option to connect a mainboard to three door IO boards or to connect four door IO boards together using t...

Страница 23: ...t of chassis together a For example if there are six boards in the control panel there would be a MAIN BOARD and five expansion boards E1 E2 E3 E4 and E5 Each expansion board could be either a DOOR BOARD or an INPUT OUTPUT BOARD b To daisy chain the boards together See Figure 11 below Wire E5 to E4 in Expansion Chassis 2 Wire E4 in Expansion Chassis 2 to E3 in Expansion Chassis 1 Wire E3 to E2 in ...

Страница 24: ...ins attached on the first and last board s in the daisy chain i e It must be removed from all boards except the endpoint of the daisy chain NOTE The MAIN BOARD does not have to be an endpoint in the control panel the control panel may be in the middle of the chain with expansion boards branching out in either direction 7 On the first board connect the wires of the CAT5 CAT6 cable to the CAN BUS te...

Страница 25: ...s are used to set the address of each board on the CAN BUS DO NOT ASSIGN TWO BOARDS THE SAME ADDRESS OR THE BUS WILL NOT FUNCTION PROPERLY Set these values sequentially starting with 2 as the first expansion board address address 1 is the MAIN BOARD Record all addresses on the Installation Worksheet These jumper settings will map to board numbers when the control panel is configured via the applic...

Страница 26: ... the completed Installation Worksheet make the following connections NOTE Doors can be wired to the MAIN BOARD or to expansion boards including both DOOR BOARDs and INPUT OUTPUT BOARDS Figure 14 Wire Doors for Wiegand Readers NOTE ACS6000 Output Ratings for the ACS6000 Main Board Two 2 reader ports 12V 350mA each Two 2 selectable wet contacts 12VDC 350mA each Four 4 dry contacts are 28VDC 6A each ...

Страница 27: ...a Door Open condition When the switch is closed the control panel interprets this input as a Door Closed condition This circuit provides door status information open closed to the control panel so the application can take appropriate action locally or send email notifications if necessary 2 Wire the DOOR LOCK RELAY terminal block a Connect the door latch to the COM terminal and either the NO or NC...

Страница 28: ... RS 485 Wiegand Door 1 switch in the Wiegand position For Door 2 put the RS 485 Wiegand Door 2 switch in the Wiegand position Important RS 485 Wiring Information NOTE Ensure that when wiring the RS 485 bus that BOTH ENDS of the RS 485 bus are terminated using a 120𝛺 resistor NOTE The ACS6000 control panel has an RS 485 termination switch built in for the Door 1 and Door 2 nodes If the ACS6000 cont...

Страница 29: ...485 Wiegand Switch Locations NOTE The ACS6000 board defaults to Half Duplex communication when using RS 485 reader functionality In order to switch to Full Duplex communication move the Door 1 FDX HDX switch on Door 1 and Door 2 FDX HDX switch on Door 2 to the Full Duplex position If placing into Full Duplex mode be careful as most readers will typically operate in Half Duplex mode ...

Страница 30: ...BOARD for Door 1 put the FDX HDX Door 1 switch in the HDX position For Door 2 put the FDX HDX Door 2 switch in the HDX position Figure 17 RS 485 Full Duplex Half Duplex Switch Locations for Doors 1 and 2 NOTE RS 485 bus requires termination Door 1 RS 485 Term is the RS 485 Door 1 bus termination switch and Door 2 RS 485 Term is the RS 485 Door 2 bus termination switch To enable RS 485 bus terminat...

Страница 31: ...Door Node 1 and Door 2 Wet Dry Switch above Door Node 2 To enable wet mode for Door 1 put the Door 1 Wet Dry Select Switch in the Wet position To enable wet mode for Door 2 put the Door 2 Wet Dry Select Switch in the Wet position To enable dry mode for Door 1 put the Door 1 Wet Dry Select Switch in the Dry position To enable dry mode for Door 2 put the Door 2 Wet Dry Select Switch in the Dry posit...

Страница 32: ...e to the GND terminal This is the standard Ground circuit for the reader Connect the blue reader wire to the BUZZ terminal This is the standard Buzzer circuit for the reader Connect the red reader wire to the 12VDC terminal This provides 12VDC to power the reader Connect the orange reader wire to the GRN LED terminal This is the green LED circuit Connect the brown reader wire to the RED LED termin...

Страница 33: ...PPLIED WITH THE CONTROL PANEL a Install the MOV across the conductors as close as possible to the electric strike or latch This will normally be at the connection from the field installed wiring to the pig tail or screw terminals of the electronic strike or latch b Use the wire recommended by the manufacturer of the electric strike or latch If no wire is recommended use a minimum of 18 AWG wire wi...

Страница 34: ...and closed switches but cut and short circuited lines as well This can only happen when the EOL end of line resistor wiring is installed a You will need two 2K ohm resistors for each input b The resistors are installed on the input lines as close to the switch as possible and as far from the ACS6000 control panel c One resistor is placed in parallel with the switch so that one end of the resistor ...

Страница 35: ... Resistor Wiring WARNING Powering Electronic Strikes and Latches DO NOT POWER ELECTRONIC STRIKES AND LATCHES WITH THE BATTERY OR OTHER POWER SOURCE USED TO POWER THE CONTROL PANEL DOING SO WILL CAUSE DAMAGE TO THE BRIVO CONTROL PANEL USE ONLY A UL LISTED BURGLAR ALARM OR ACCESS CONTROL SYSTEM TO POWER ELECTRONIC STRIKES AND LATCHES ...

Страница 36: ...ith one end being a brass washer screw connector which is covered by a removable red protective cover and the other end being a silver snap connector 3 Unscrew the brass washer from the cable and place that end through the top of the chassis Now screw the washer back in place on the outside of the chassis securing the cable to the top of the chassis 4 Attach the Wi Fi antenna included with the shi...

Страница 37: ...into place you may feel and hear an audible click Ground the control chassis 1 Wire the incoming Earth ground cable to the control chassis Earth ground screw located at the bottom of the chassis 2 Use 18 AWG or larger wire to connect the chassis to a suitable earth ground 3 The ground contact point is in the lower panel area near the hinge for the door and in front of the power supply ...

Страница 38: ...nstall the latest firmware This process may take several minutes so do not disconnect or cut power to your ACS300 during this process If you encounter any difficulties please contact Brivo Technical Support at 866 274 8648 or email customercare brivo com 2 Check ALL power indicators a Once the chassis door is closed check the power supply board through the clear viewing hole to confirm that the gr...

Страница 39: ...the LOCAL HRTBT has come on and is blinking e If any of these power indicators is not correct i e the LED light does not come on or does not begin blinking check the connections from the power supply to each of the circuit boards If all connections are good but there is a still a problem with the power indicator contact Technical Support NOTE A steady light is an indication of a problem just as mu...

Страница 40: ...the local administrative interface for debug and manual configuration utilities b The port uses auto sensing technology to determine polarity which permits either a straight or crossover cable to be used between the board and the computer Connect the LAN to the MAIN BOARD if required Figure 29 Connect LAN to MAIN BOARD 1 Connect the LAN to the MAIN BOARD according to the instructions in the Panel ...

Страница 41: ...avior represents the network speed for the LAN port on the ACS6000 control panel Green LED only 1000 M Orange LED only 100 M Green LED Orange LED 10 M NOTE Since each OSDP reader is on a separate bus on the ACS6000 board the RS 485 default address assigned to each reader should not interfere with any other OSDP readers assigned to the same control panel However make certain that the default OSDP r...

Страница 42: ...t 1 5 5 17 2017 LMW Removed reference to ACS6000 S and Brivo Onsite 1 6 11 7 2017 LMW Replaced references to Reader Keypad Wiring Guide with Approved Wiegand and OSDP Reader List and added SW 7 7 functionality description 1 7 11 22 2017 LMW Added LAN port behavior information denoting network speed 1 8 10 29 2018 LMW Added information about the pre assembled CAN Bus connection cable 1 9 06 19 2019...

Отзывы: