6
2.0 ICEBOX DIMENSIONS
Diagram 1:
Icebox Unit Dimensions
All dimensions in [mm]
2.1 Service Clearances
For servicing, a minimum clearance of 750mm shall be provided on the sides and 500mm from the front
of the unit, as shown in Diagram 2, and extend vertically to one meter above the heater roof.
Consideration shall be made for flue terminal location and clearance requirements; refer to heater
installation manual.
Diagram 2:
Icebox Service Clearances
Model
A
B
C
D
E
Duct
ØRA
Duct
ØSA
Flare
ØLL
Flare
ØSL
DINIB10Z7-L
772 844 392
670 460
350 350
9.5
15.9
DINIB10Z7-R
670 460
DINIB13Z7
956
881 566
846 417
19.05
DINIB15Z7
1026
955 496 400 400
Power
Lead 2.5m
Condensate
Drain 3/4” BSP
A
Ø
SA
Ø
RA
Liquid Line (LL)
Suction Line (SL)
Communication Loom Access
D
C
B
E
Service Clearance
500
750
Building Wall
750