background image

Please keep this booklet for future 

reference.
Installer, when you have read these 

instructions please ensure you leave 

them with the user.

Installation 

Instructions and User 

Guide

Elvira Exposed Sequential 

Shower Pack & Exodus 

Thermostatic Surface Mounted 

Mini Shower Valve

Models covered: 

 

ELVIRA SHWR PK, EXD SHXAR C

Содержание ELVIRA SHWR PK

Страница 1: ...when you have read these instructions please ensure you leave them with the user Installation Instructions and User Guide Elvira Exposed Sequential Shower Pack Exodus Thermostatic Surface Mounted Mini...

Страница 2: ...ul installation and should be left with the user All products manufactured and supplied by Bristan are safe providing they are installed correctly and receive regular maintenance in accordance with th...

Страница 3: ...e starting installation Warning Before starting any installation please consider the following Prior to drilling into walls check that there are no hidden electrical wires cables or water supply pipes...

Страница 4: ...e minimum distance from the highest installed position of the showerhead to the underside of the cold tank should be at least 1 metre to ensure adequate performance Note Nominally equal balanced inlet...

Страница 5: ...peak to one of our trained advisers Product Features On Off and Temperature Control Turn the control anti clockwise to turn the shower on and increase the temperature Turn the control clockwise to de...

Страница 6: ...ximum Static Pressure 10 bar Maximum outlet temperature Factory pre set to 42 C can be re set to suit site conditions Supply requirements Minimum cold water supply temperature 5 C Maximum cold water s...

Страница 7: ...7 Need help Give us a call on 0330 026 6273 and speak to one of our trained advisers Dimensions mm s 110 155 Centres 95 34 685 ELVIRA SHWR PK handset is shown in drawing...

Страница 8: ...wer Valve 2 Covers x 2 3 Filters x 2 Pre fitted 4 Long Elbows x 2 5 Green flow regulator Pre fitted 6 Yellow flow regulator Pre fitted 7 Backplate fixings x 2 8 Shower head Multifunction 9 Sealing was...

Страница 9: ...ty Fed Hot and Cold Gravity Fed Hot and Mains Cold cold mains supply cold mains supply Important If you install this shower valve with a gravity fed system there must be a minimum head vertical distan...

Страница 10: ...llation Requirements Unvented System Instantaneous Water Heater Pumped System cold mains supply cold mains supply cold mains supply Pumped System with Essex flange cold mains supply 1m min Key 1m min...

Страница 11: ...nstalled as either a or b below a with an approved double check valve assembly or some other no less effective backflow prevention device immediately upstream of the inlet b so that it draws water by...

Страница 12: ...41 C for showers The mixed water temperatures must never exceed 46 C The maximum mixed water temperature can be 2 C above the recommended maximum set outlet temperatures Note 46 C is the maximum mixed...

Страница 13: ...1 to 5 bar or pumped Green 7 litre Yellow 5 litre Use arrangement for pumped system Mains 1 0 10bar Gravity 0 1 to 0 5 bar Green 7 litre No Gravity above 0 5 bar Green 7 litre Yellow 5litre Unvented...

Страница 14: ...y using a flow stabiliser fitted prior to the heater and should be adjusted to give a temperature of between 45 500C from the heater Flow regulators are factory fitted Study the table on the previous...

Страница 15: ...elbow configuration to suit Inlet centres 2 x small elbows 110 130 centres 2 x large elbows 136 155 1 small elbow 1 large elbow 125 145 All measurements are in millimetres To remove the elbows To rem...

Страница 16: ...ed With the elbows screwed fully against the valve body it can be unscrewed a maximum of 1 5 turns to allow for lateral tolerance Sufficient 15mm diameter supply pipes should protrude through the fini...

Страница 17: ...pipes into the inlet connections and tighten the nuts Ensure the olives are fitted to the water supply pipes Secure the shower valve to the backplate by tightening the backplate grub screw Re attach t...

Страница 18: ...he shower and the length of the hose when connected to the shower and passed through the hose retainer Mark the wall to indicate the upper and lower fixing screw position ensur ing they are straight N...

Страница 19: ...ntrol Turn the lever anti clockwise to turn on and increase the temperature Turn the lever clockwise to decrease the temperature and turn off Riser Rail Push and hold the slider button to al low the s...

Страница 20: ...solating the cold water supply to the TMV wait for five seconds if water is still flowing check that the temperature is below 46 C If there is no significant change to the set outet temperature 20C or...

Страница 21: ...ombined with constant use means you may need to clean your showerhead once a week To ensure continued performance of your shower the showerhead needs to be regularly descaled Cartridge Maintenance We...

Страница 22: ...ome ter If the temperature is not correct re calibrate the shower valve 1 Turn the lever anti clockwise to the maximum temperature position 2 Remove the lever remove the plastic cap loosen the grub sc...

Страница 23: ...ct the boiler manufacturer Head of water is below the minimum distance required Raise the cistern or fit a shower booster pump Inlet filter is partially blocked Clean or replace flush through pipework...

Страница 24: ...lve Flow control valve seals damaged Check condition of flow control valve and replace if necessary Maximum water temperature too hot or cold Maximum water temperature set incorrectly Reset maximum wa...

Страница 25: ...ase water flow rate through the system Check inlet filters and clean or replace Refer to Maintenance section pages 21 22 Contact the boiler manufacturer Instantaneous water heater not igniting because...

Страница 26: ...oducts effective from the fate of purchase to give you peace of mind To start your free guarantee simply scan the QR code and register your product Alternatively visit www bristan com register For any...

Страница 27: ...lp Give us a call on 0330 026 6273 and speak to one of our trained advisers Notes Please use this space to add any notes you or your installer may have regarding the plumbing system installation of th...

Страница 28: ...G Web www bristan com Email enquire bristan com A Masco Company Part Number ELVIRA SHWR PK EXD SHXAR C Issue D1 Useful contact details Customer Service 0330 026 6273 Customer Service Email Customercar...

Отзывы: