Specifications

Maximum Static Pressure:

 10.0 bar

Inlet Water Temperature

Min:

 

0.2 bar

Max:

 5.0 bar

Dynamic Water Pressure

5°C

25°C

Cold Water Supply

Min:

 5°C 

Max:

 25°C

65°C Recommended

Tools You’ll Need

Hot Water Supply

Pack Contents

65°C

150

Centres

15mm 

Compression

 

Inlet Connections

Inlet Dimensions

IMPORTANT

The inlet hot water must  

be at least 10°C above the  

required blend temperature.

Cavity Depth: 

35mm

Concealing Plate  

Adjustment Range: 

30mm

 

Cavity Dimensions (mm)

35

30

45

120

x3

x3

x4

x1

x2

x1

x1

Flat head  

Screwdriver

Silicon Sealant

Hexagonal Keys

Pipe Cutter

Drill

Adjustable Spanner

Hot

Cold

4

3

2

Secure the 

valve using 

the screws 

supplied  

(solid walls 

only) or a 

suitable  

alternative.  

Connect the inlet 

pipes ensuring the  

olives are fitted. 

Screw the 

shrouds 

onto the 

valve.

Pipe & Wire Detector

Plumb the 

valve into 

your chosen 

outlets

.

 

Elbows can 

be point

ed up 

or down

Fit the handles.

6

2

2.5

mm

Turn the  

temperature stop  

to increase or  

decrease the  

temperature.  

Check the  

temperature and 

adjust until you 

achieve the  

desired result.

Increase  

Temperature

 

Decrease  

Temperature

 

Pre-set t

42

°

C

 

   Finish the     

            wall surface,  

       ensuring there  

      is at least a 10mm 

gap between the 

cavity and the edge 

of the face plate.

Using a silicon  

sealant, push on the 

concealing plate and 

hold firmly until set.

5

Socket Spanner

3

1

2.5

mm

Fit the temperature  

handle back in the  

maximum hot position.

2.5

mm

Turn the handle to the 

maximum temperature  

setting, then remove it.

Temperature Adjustment

REMEMBER 

To service 

your 

product!

x3

2

Green Flow  

Limiter (Cold)

1

Valve Configuration

Remove the inlet elbows and filters.  

Remove the plastic inserts from the valve  

inlets and insert the flow regulators.  

Replace the elbows, ensuring the  

filters are fitted.

   

 IMPORTANT 

If installed in 

 

conjunction with 

 

combination  

boiler flow  

regulators  

must

 be  

fitted.

Yellow Flow 

Limiter (Hot)

1

Installation

REMEMBER 

hot on the left, 

cold on the 

right

Min 35mm

Max 45mm

Batons

Install suitable 

batons  

(if required) onto 

the rear cavity. 

Mark the position 

of the valve  

and drill and plug 

holes to suit. 

 

Installation Instructions 

& User Guide

Prior to Installation

Please leave these instructions 

with the end user

All products manufactured and supplied by Bristan are safe to use  

provided that they are installed, operated and receive regular  

maintenance in accordance with these instructions. 

This product needs to be installed in accordance with, and meet the 

requirements of the Water Supply (Water Fittings) Regulations 1999  

and current by-laws. For full Installation Requirements & Notes (IRN) 

please visit 

wras.co.uk/directory. 

Isolation valves must be fitted to the inlet water supplies to ensure ease 

of future maintenance. Before installing this product the water supply 

must be thoroughly flushed in order to remove any swarf, solder etc.  

Full access must be made available for future maintenance/ 

servicing purposes.

Before drilling into walls, check that there are no hidden electrical  

wires, cables or water supply pipes. This can be checked with the  

aid of an electronic detector.

If power tools are used do not forget to:  

 

- Wear eye protection

 

- Unplug equipment after use

This product must not be modified in any way  

as this will invalidate the guarantee.

If in doubt, contact a registered plumber, your Local Water  

Authority or the Secretary of the Institute of Plumbing,  

address as follows:-

The Institute of Plumbing,

64 Station Lane,

Hornchurch,

Essex,

RM12 6NB, Tel: 01708 472791

Product Code: DSC SHC3DIV C (D6)