Hot Gun for Composite Curing 

 
 

 
A person who has not read 
and  understood all operating 
instructions is not qualified to 
operate this product. 

 

Do not immerse heater in liquid. 

 

Keep volatile or combustible material away from 
heater when in use. 

 

Use heater only in approved locations 

 

Keep sharp metal objects away from heater. 

 

Failure to observe these warnings may result in  
electric shock, risk of fire, and personal injury. 

 

Only qualified personnel are allowed to connect 
the electrical wiring. 

 

Disconnect all supply power at the source before 
making any heating cable power input connec-
tions. 

 

All electrical wiring must follow local electrical 
codes and highly recommend following NEC 
Article 427. 

 

Final installation / wiring is to be inspected by 
the authority who has jurisdiction in the area that 
the heater is installed. 

 

The end-user is responsible for providing a 
suitable disconnecting device. 

 

The end-user is responsible for providing suita-
ble electrical protection device.  It is highly rec-
ommended that a ground fault circuit breaker be 
used. 

IMPORTANT SAFETY INSTRUCTIONS 

 

Never handle the heater while it is 
in operation; always disconnect the 
heater from the power source and 
allow to cool prior to handling. 

 

Inspect heater and connection kits 
before use.   

 

Never operate heater without a 
temperature control device. 

 

Do not wrap the heating cable over 
itself 

 

If spillage of foreign matter onto 
heater occurs, disconnect from 
power source and clean after heat-
er is allowed to cool 

 

Never operate a heater without an 
appropriate heat sink (device being 
heated is considered a heat sink) 

 

Do not operate heater above rated 
temperature value 

 

Fasten heater to device using 
approved methods only 

 

Do not repair damaged or faulty 
heaters. 

 

Do not crush or apply severe physi-
cal stress on heater or cord assem-
bly. 

 

Disconnect heater when not in use.

 

 

Failure to observe these warnings may 
result in personal injury or damage to the 
heater. 

Содержание BRISKAIRSP-1

Страница 1: ...before installing this heater Failure to understand how to safely install the heater could result in an accident causing serious injury or death This heater should only be installed by qualified personnel Instruction Manual BRISKAIRSP 1 ...

Страница 2: ...lert to the possibility of personal injury or death Immediate hazards which WILL result in severe personal injury or death Hazards or unsafe practices which COULD result in severe personal injury or death Hazards or unsafe practices which COULD result in minor personal injury or property damage SAVE THESE INSTRUCTIONS Additional copies of this manual are available upon request Thank you for purcha...

Страница 3: ...sible for providing a suitable disconnecting device The end user is responsible for providing suita ble electrical protection device It is highly rec ommended that a ground fault circuit breaker be used IMPORTANT SAFETY INSTRUCTIONS Never handle the heater while it is in operation always disconnect the heater from the power source and allow to cool prior to handling Inspect heater and connection k...

Страница 4: ...ting of heater is appropriate for power supply device or temperature controller The heater is designed to work at a specific voltage to heat properly For additional infor mation contact BriskHeat HOT GUN SET UP 1 Perform composite lay up of mounting pin 2 Place hot gun into the metal stand with the handle facing upwards Figure 1 Secure hot gun in place with provided hook and loop fastener strap 3 ...

Страница 5: ... to the gun Figure 3 For best results ensure that the tip of the thermocouple is on the bond line but not touching the adhesive and the entire assembly is covered with aluminum tape Plug the process control thermocouple attached to the pin to the controlling thermocouple input on the back of the TTQSD S16temperature controller Figure 4 Firugre 4 6 Place the output hot gun nozzle 2 50mm from the bo...

Страница 6: ...trical connections must be made by qualified personnel and in accordance with all applicable codes and regulations 1 Ensure heater is protected by a properly rated circuit breaker or fuse 2 Use of a ground fault circuit interrupter GFCI is highly recommended and may be required according to local electric code 3 Plug TTQ3D 16 Controller into wall outlet 4 Adjust the airflow dial on the back of the...

Страница 7: ...ater using an ohm meter Circuit breaker is tripping Verify that the circuit breaker is capable of handling the amperage requirement of heater The identification label located on the power cord displays the heater s amper age requirement Examine heater and cord for any damage Check to see if there is a resistance reading between power leads and the ground lead Significant temperature deviations dur...