Brisas BMI-E30CG Скачать руководство пользователя страница 1

Use, Care, and Installation Guide

Model number: 
Serial Number: 

MAR19.0101 

BMI-E30CG

BMI-E36CG

BVE-E30BS

BVE-E36BS

Содержание BMI-E30CG

Страница 1: ...Use Care and Installation Guide Model number Serial Number MAR19 0101 BMI E30CG BMI E36CG BVE E30BS BVE E36BS...

Страница 2: ......

Страница 3: ...Options 7 Hood Specifications 8 9 Mounting the Hood BMI 10 Mounting the Hood BVE 11 Ductless Recirculating 12 FEATURES CONTROLS Touch Controls 13 MAINTENANCE Hood and Filter Cleaning 14 Lights 15 ACT...

Страница 4: ...EVENT OF A RANGE TOP FIRE OBSERVE THE FOLLOWING a SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out im...

Страница 5: ...e and in conformance with National Electrical Code ANSI NFPA 70 latest edition or CSA standards C22 1 94 Canadian Electrical Code Part 1 and C22 2 No 0 M91 latest edition and all local codes and ordin...

Страница 6: ...DELS BMI E30CG BMI E36CG BVE E30BS BVE E36BS 1 Hood with internal blower 1 Duct cover wall bracket 1 Duct cover assembly top and bottom 1 6 round backdraft damper pre installed 1 5W LED light strip pr...

Страница 7: ...lumn 2 Subtotal column 1 Total ductwork Maximum Duct Length For satisfactory air movement the total duct length should not exceed 100 equivalent feet 6 roundto 3 1 4 x 10 rect transition 1 Ft x Ft 6 r...

Страница 8: ...rd while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer to range manufacturer s height clearance requirements and recommended hood m...

Страница 9: ...ng option Use single wall rigid Metal ductwork only Fasten all connections with sheet metal screws and tape all joints w certified Silver Tape or Duct Tape Some Ducting Options Installation Ducting Op...

Страница 10: ...Installation BMI Hood Specification 17 1 4 8 15 16 15 7 8 6 7 8 19 3 4 10 5 8 23 15 16 10 3 8 29 15 16 or 35 3 16 Min Ducted 23 Min Recirc 27 1 2 Maximum 42 FRONT SIDE TOP BACK 8 3 8 3 15 16 1 3 16 6...

Страница 11: ...16 13 16 3 15 16 8 3 4 29 15 16 or 35 7 8 1 9 16 6 3 4 19 3 4 12 13 5 16 12 5 16 Min Ducted 27 1 2 Min Recirc 32 Maximum 42 1 2 4 1 3 FRONT SIDE TOP BACK 2 3 1 2 C L C L Installation BVE Hood Specific...

Страница 12: ...screws FIG A 3 9 Install duct work and seal with aluminum duct tape Re install junction box with cable lock and install the electrical FIG B 2 10 Power up hood to verify all functions and check for l...

Страница 13: ...hood 8 Center and attach duct cover bracket to wall below ceiling or soffit using 2 6 x1 screws 8 Install electrical and duct work Seal duct work with aluminum duct tape 9 Power up hood and check for...

Страница 14: ...ooking and the optional charcoal filters help to purify fumes exhausted from cooking for re circulation RECIRCULATING KIT REQUIRED IF NO DUCTING IS USED Hood Model Part No Filters in Pkg BMI BRC 0006...

Страница 15: ...and regulations To verify the maximum fan CFM With hood off press and hold the power button for five seconds If all three fan speed indicators illuminate default maximum CFM If two speed level indicat...

Страница 16: ...an cotton cloth or micro fiber cloth and buff in the direction of the stainless steel grain Aluminum Mesh Filters The aluminum mesh filters installed by the factory are intended to filter out residue...

Страница 17: ...d accessories page for part s and contact information To replace LED light strip 1 Remove aluminum mesh filters 2 Remove light panel by two screws 3 Disconnect LED light strip quick connector 4 Push i...

Страница 18: ...nother clearly visible location NOTE After re positioning the jumper and powering on the hood the CFM cannot be changed again To verify if your installer enabled ACT With hood off press and hold the p...

Страница 19: ...17 Fan 310W Lamp LED 5W Total Max 320W 2 66A Voltage 120V 60Hz Power consumption UL file number E127334 THERMALLY PROTECTED Model BMI E30CG BMI E36CG Fan On Off Lights Wiring Diagrams MAX 320W 2 66A...

Страница 20: ...tor is not secure in place 1 Tighten the motor in place 2 Damaged blower wheel 2 Replace the blower 3 The hood is not secured in place 3 Check the installation of the hood 4 The switch board or contro...

Страница 21: ...m Mesh Filter 50200044 BVE Optional Accessories Recirculating Kit BRC 0006 BMI Recirculating Kit BRC 0008 BVE Replacement Charcoal Filter Z0F C093 BMI Replacement Charcoal Filter Z0F C091 BVE Duct Cov...

Страница 22: ...y All Products must be installed by a qualified professional installer to be eligible for warranty repairs or service Limitations of Warranty OUR OBLIGATION TO REPAIR OR REPLACE AT OUR OPTION SHALL BE...

Отзывы: