background image

BE3928 

Operating Instructions 

(Translation of original)

 

©

 Brinkmann Pumpen 

Edition

 05/2022 

Page

 1 

of

 14 

 

BRINKMANN Immersion Pumps             

                                                     STH21

…STH28 

 
Brinkmann Pumpen 
K. H. Brinkmann GmbH & Co. KG 

Friedrichstraße 2    D-58791 Werdohl 

Tel.:  +49-2392 / 5006-0  

www.brinkmannpumps.de 

Fax.: +49-2392 / 5006-180  

[email protected] 

 
Subject to change without prior notice.

  

Order - No. : BE3928 ENGLISH 

 

Содержание STH21 Series

Страница 1: ...2022 Page 1 of 14 BRINKMANN Immersion Pumps STH21 STH28 Brinkmann Pumpen K H Brinkmann GmbH Co KG Friedrichstra e 2 D 58791 Werdohl Tel 49 2392 5006 0 www brinkmannpumps de Fax 49 2392 5006 180 sales...

Страница 2: ...tary pumps Series TH STH use closed impellers in order to minimizing power consumption and to optimize hydraulic pump efficiencies In addition the STH series offers high pressures at short immersion d...

Страница 3: ...410 STH2103 0A410 6 7 8 2 200 900 688 407 151 11 0 74 STH2104 2A490 STH2104 0A490 9 4 10 8 200 900 982 482 170 15 0 78 STH2105 2A560 STH2105 0A560 12 0 13 4 200 900 1042 557 182 18 5 78 STH2106 2A640...

Страница 4: ...1350 680 362 129 9 0 74 STH2802 0A370 5 9 250 1350 688 362 151 11 0 74 STH2803 2A460 7 4 250 1350 982 452 171 15 0 78 STH2803 0A460 8 9 250 1350 1042 452 181 18 5 78 STH2804 2A550 STH2804 0A550 10 6...

Страница 5: ...680 332 126 10 3 77 STH2102 0B340 8 0 200 1200 688 332 147 15 0 79 STH2103 2B410 9 7 200 1200 982 407 167 17 3 81 STH2103 0B410 11 8 200 1200 1042 407 177 21 3 81 STH2104 2B490 13 5 200 1200 1046 482...

Страница 6: ...TH2801 0B280 4 2 250 1550 680 272 125 10 3 77 STH2802 2B370 6 4 250 1550 688 362 150 15 0 79 STH2802 0B370 8 6 250 1550 1042 362 177 21 3 81 STH2803 2B460 10 7 250 1550 1046 452 192 25 3 81 STH2803 0B...

Страница 7: ...ards they must be guarded against accidental contact Guards for moving parts e g coupling must not be removed from the machine while in operation Any leakage of hazardous e g explosive toxic hot fluid...

Страница 8: ...service work must be carried out by qualified service personnel Pump must be disconnected from the power source and all rotating parts must stand still Reassure that pump is discon nected from power...

Страница 9: ...there is no voltage at the terminal board Open terminal box and disconnect the power leads Empty out the pump 7 Operation Liquid level Be sure that the suction hole of the pump body is immersed about...

Страница 10: ...e above Clean pump mechanism repair pump Motor overheats High on off cycling frequency Wrong power supply voltage or cycles Insufficient cooling See above Power supply must correspond with name plate...

Страница 11: ...d cap screw DIN 912 23 Bearing cover 7 5 kW and over 24 Hexagon head cap screw 7 5 kW DIN 931 25 Shaft nut 7 5 kW and over 26 Compensation disk 27 O ring 28 Shaft seal 29 Rotary shaft seal 30 Nut up 1...

Страница 12: ...51 Casing cover 52 Adapter 53 Intake cover 54 Pump shaft 55 Diffusor 56 Bearing stage with venting bore 57 Outflow stage 59 Impeller 60 Spacer sleeve Mechanical seal 61 Spacer sleeve start 62 Spacer s...

Страница 13: ...casing cover 51 Note the position of the fixing groove relative to the pin Slide the rotating mechanical seal unit 81 2 on to the spacer sleeve 60 via the pump shaft 54 Attention the 3 pins of the me...

Страница 14: ...006 42 EG die Schutz ziele der Niederspannungsrichtlinie 2014 35 EU eingehalten With respect to potential electrical hazards as stated in appendix No 1 5 1 of the machine guide lines 2006 42 EC all sa...

Отзывы: