Renovent Sky 200 Rev. C
33
10.5 Connection postheater or extra preheater
The postheater or extra preheater (only possible for Renovent
6N\3OXVDUHHOHFWULFDOO\FRQQHFWHGWRFRQQHFWRU;MXVWIRU
a postheater there is also a temperature sensor that must be
connected to no. 7 and 8 of the 9-pole connector that is only
installed in the Plus version.
When using a postheater or extra preheater, step number 11 is
applied (and for extra preheater also step number 12). Please
refer to the mounting instructions that came with the heater for
more extensive information regarding installation of the post-
heater or the extra preheater.
X14
*)
*
) The strain reliever to be installed by the installer (not supplied with the appliance) for feeding
the 230 volt cable to the postheater or extra preheater.
Temperature sensor postheater 7 - 8.
Chapter 10 Electric connections accessories
Connection
postheater
1
2
3
4
5
6
7
8
9
X14
230V
50Hz
X14
230V
50Hz
7 & 8
×
IV
II
I
III
1 2 3 4 5 6 7 8 9
*
)
Setting parameter
11 & 12 (§12)
Setting
parameter 11 (§12))
X14
Connection
extra preheater
230V
50Hz
×
230V
50Hz
X14
*
)
Содержание Renovent Sky 200
Страница 1: ...Renovent Sky 200 Plus WWW BRINKAIRFORLIFE NL 614485 C INSTALLATION INSTRUCTIONS English ...
Страница 2: ......
Страница 17: ...Renovent Sky 200 Rev C 13 Chapter 5 Installation A A X A 1 2 3 4 A t 60 mm t A ...
Страница 18: ...14 Renovent Sky 200 Rev C Chapter 5 Installation A A X A 1 2 3 4 A t 60 mm t A ...
Страница 32: ...28 Renovent Sky 200 Rev C Chapter 8 Maintenance 12 13 14 15 16 4x 3x 17 ...
Страница 47: ......