Renovent Sky 200 Rev. C
15
5.4 Electric
connections
5.4.1 Connecting the power plug
The appliance comes ready to plug in with a 230 V mains plug
Make allowance for the 375 W preheater; if in addition also
a postheater or extra preheater is installed, the rated pow-
er increases to 1375 W.
The appliance can be connected to an easily accessible, earthed wall socket with the plug that is mounted to the appliance. The
electric installation must comply with the requirements of your power company.
Warning
The fans and control board carry a high voltage. Al-
ways take the voltage from the appliance by pulling
the power plug when working on the appliance.
³%ULQN$LUFRQWURO´FRQQHFWLRQ
The “Brink Air control” that comes as standard with the appliance must be connected to the eBus connector. This (detachable) 2-pole
eBus connector is mounted on the outside of the appliance (see also §10.1).
nr.1
nr.2
Cables to be connected by installer
(wire diameter at least 0,34 mm
2
)
Chapter 5 Installation