background image

Wireless humidity sensor

English

Installation regulations

Содержание 616860-B

Страница 1: ...Wireless humidity sensor English Installation regulations...

Страница 2: ...on the wall 7 3 2 Remove Wireless humidity sensor from wall bracket 8 3 3 Connecting the AC DC converter option 8 3 4 Using another frame option 10 4 Put into use 11 4 1 Connecting additional Wireles...

Страница 3: ...in image below The Wireless humidity sensor should only be used in combination with products that have been approved by Brink Climate Systems B V The Wireless humidity sensor can only be used together...

Страница 4: ...rollers sensors are used the controller sensor that requests the highest ventilation level always has priority The air flow quantities associated with the ventilation settings must always be set on th...

Страница 5: ...0 Other For indoor use Max distance between USB transceiver and Wireless humidity sensor 300 m open field 1 meter height 2 2 Environment influences The Wireless humidity sensor should be placed and us...

Страница 6: ...e for note ID 3 4 Button 3 Not visible but available for note ID 4 5 Fault indication LED 5 Button 1 2 3 4 When the not visible buttons 1 2 3 4 are operated for a note ID see Connecting additional Wir...

Страница 7: ...of approximately 1 65 meters above the floor Screw or glue the wall bracket onto the wall in the correct position Take note The up arrow on the wall bracket must point upwards Backside wall bracket wi...

Страница 8: ...ould be performed to connect the optional 5V AC DC converter Step 1 Place the converter in the wall box The 230V power supply must be connected to the factory mounted gray connectors Strip the wire ov...

Страница 9: ...nt Step 5 When the Wireless humidity sensor has been fitted on the wall the USB transceiver can be placed in the USB port of the appliance which must be connected with the Wireless humidity sensor To...

Страница 10: ...that a large number of frames from other vendors also can be used The following types of frames can also be used instead of the standard frame A Gira System 55 A B Busch Jaeger Reflex S1 B C Jung AS C...

Страница 11: ...the HRU appliance Step 2 Press the pairing button of the USB transceiver 2 sec 10 sec The green LED on the USB transceiver starts flashing 1x per second The pairing mode is active for 10 minutes Step...

Страница 12: ...ies in the menu of the device If pairing is not successful go back to Step 4 Check also the USB transceiver The air flow quantities associated with the ventilation settings must always be set on the c...

Страница 13: ...ng button for example with end of a paper clip for more than 20 seconds To confirm this reset all LED s will flash two times All the pairing information has been deleted from the Wireless humidity sen...

Страница 14: ...d the battery voltage is too low Not applicable if the optional 230 volt power supply interface is used Replace battery with correct type CR2032 MRF battery manufacturer Renata or Panasonic CR 2032 BS...

Страница 15: ...oting re use recycling and other forms of recovering such waste in order to limit the amount of waste The WEEE logo on a product or on the packaging indicates that this product may not be disposed of...

Страница 16: ...You then have to make that known in writing via Brink Climate Systems B V P O Box 11 NL 7950 AA Staphorst The Netherlands The right to guarantee lapses in case of incorrect or improper use of the Wir...

Страница 17: ...ment directive RoHS 2011 65 EU substances directive The product described above has been tested according to the following standards EN 62368 1 2020 EN 62479 2010 EN 60669 2 5 2016 EN 60730 1 2016 Saf...

Страница 18: ...Brink Climate Systems B V P O Box 11 NL 7950AA Staphorst T 31 0 522 46 99 44 E info brinkclimatesystems com www brinkclimatesystems com 616860 B...

Отзывы: