background image

BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC EQUIPMENT OWNER WARRANTY POLICY

LIMITED WARRANTY

Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s), of the equipment that is defective in material
or workmanship or both. Transportation charges on parts submitted for repair or replacement under this warranty must be borne by
purchaser. This warranty is effective for the time periods and subject to the conditions stated below. For warranty service, find the nearest
Authorized Service Dealer in our dealer locator map at www.briggspowerproducts.com.

THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW ANY
AND ALL IMPLIED WARRANTIES ARE EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED
TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some states or countries do not allow limitations on how long an implied warranty
lasts, and some states or countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation
and exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state
to state or country to country.

OUR EQUIPMENT*

OUTBOARD

MOTOR

PRESSURE

WASHER

WATER PUMP

(Not available in the

USA)

PORTABLE

GENERATOR

WELDER

Less tthan 110 K

KW 10 K

KW oor ggreater

Transfer sswitch

2 years

none

1 year

90 days

1 year

90 days

2 years

1 year

2 years

none

3 years or

1500 hours

none

3 years

none

WARRANTY PERIOD**

HOME STANDBY GENERATOR SYSTEM

Consumer Use

Commercial Use

*

The engine and starting batteries are warranted solely by the manufacturers of those products.

**

2 years for all consumer products in the European Union. Parts only on 2nd year for consumer use of Portable Generator and
Home Standby Generator System - Less than 10 KW, outside of European Union.

The warranty period begins on the date of purchase by the first retail consumer or commercial end user, and continues for the period of time
stated in the table above. “Consumer use" means personal residential household use by a retail consumer. “Commercial use" means all other
uses, including use for commercial, income producing or rental purposes. Once equipment has experienced commercial use, it shall thereafter
be considered as commercial use for purposes of this warranty.

Equipment used for Prime Power in place of utility are not applicable to

this warranty. Electric Powered Pressure Washers used for commercial purposes are not warranted.

NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR
PROOF OF PURCHASE RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY
SERVICE IS REQUESTED, THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY
PERIOD.

ABOUT YOUR WARRANTY

We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs. Most
warranty repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would not
apply if equipment damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or improper installation.
Similarly, the warranty is void if the manufacturing date or the serial number on the equipment has been removed or the equipment has been altered
or modified. During the warranty period, the Authorized Service Dealer, at its option, will repair or replace any part that, upon examination, is found to
be defective under normal use and service. This warranty will not cover the following repairs and equipment:

Normal Wear:

Outdoor Power Equipment, like all mechanical devices, needs periodic parts and service to perform well. This warranty does not

cover repair when normal use has exhausted the life of a part or the equipment.

Installation and Maintenance:

This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized

installation or alteration and modification, misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair or storage so as,
in our judgment, to adversely affect its performance and reliability. This warranty also does not cover normal maintenance such as adjustments,
fuel system cleaning and obstruction (due to chemical, dirt, carbon, lime, etc.).

Other Exclusions:

This warranty excludes wear items such as quick couplers, oil gauges, belts, o-rings, filters, pump packing, etc., pumps that

have been run without water supplied or damage or malfunctions resulting from accidents, abuse, modifications, alterations, or improper servicing
or freezing or chemical deterioration. Accessory parts such as guns, hoses, wands and nozzles are excluded from the product warranty. This
warranty excludes failures due to acts of God and other force majeure events beyond the manufacturers control. Also excluded is used,
reconditioned, and demonstration equipment; equipment used for prime power in place of utility power and equipment used in life support
applications. 

BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC

JEFFERSON, WI, USA

Effective September 1, 2004 replaces all undated Warranties and all Warranties dated before September 1, 2004

Содержание 1932

Страница 1: ...lp is just a moment away Call Generator Helpline 1 800 743 4115 M F 8 5 CT Manuel de l utilisateur Vous avez des questions Vous n avez pas besoin d aller loin pour trouver de l aide Appelez Ligne d as...

Страница 2: ...right to change alter or otherwise improve the product and this document at any time without prior notice The Emission Control System for this generator is warranted for standards set by the Environme...

Страница 3: ...tains acid and is extremely caustic Contact with battery fluid will cause severe chemical burns DANGER Operate generator ONLY outdoors Keep exhaust gas from entering a confined area through windows do...

Страница 4: ...R MAKING REPAIRS TOYOUR GENERATOR Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug WHEN TESTING FOR ENGINE SPARK Use approved spark plug tester...

Страница 5: ...of intake air Choke Lever Used when starting a cold engine Data Tag Provides model revision and serial number of generator Please have these readily available if calling for assistance Fuel Tank Capa...

Страница 6: ...g Locking 120V 30A plug Wheel kit If any parts are missing or damaged call the generator helpline at 1 800 743 4115 INSTALL WHEEL KIT The wheel kit is designed to greatly improve the portability of yo...

Страница 7: ...Refer to engine owner s manual and follow oil recommendations and instructions NOTE Check oil often during engine break in Refer to engine owner s manual for recommendations NOTE The generator assemb...

Страница 8: ...s could accumulate and enter inside or be drawn into a potentially occupied building Ensure exhaust gas is kept away from any windows doors ventilation intakes or other openings that can allow exhaust...

Страница 9: ...ces plugged in and turned ON 2 Move idle control switch to Off position 3 Let engine run at no load for several minutes to stabilize internal temperatures of engine and generator 4 Move fuel valve to...

Страница 10: ...t engine Let engine run while battery recharges 9 When battery has charged shut down engine NOTE Use an automotive hydrometer to test battery state of charge and condition Follow the hydrometer manufa...

Страница 11: ...0 Start and run engine outdoors 11 Keep exhaust gas from entering a confined area through windows doors ventilation intakes or other openings 12 DO NOT enclose generator any more than shown in Figure...

Страница 12: ...t breaker Use each receptacle to operate 120 Volt AC single phase 60 Hz electrical loads requiring up to 2 400 watts 2 4 kW at 20 Amps of current Use cord sets that are rated for 125 Volt AC loads at...

Страница 13: ...If circuit breaker tests correctly the electrical equipment or extension cords may be faulty Replace faulty electrical equipment and cords before further use 13 BSPP Generator DO NOT touch bare wires...

Страница 14: ...ngine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load NEVER add more l...

Страница 15: ...NOT use a garden hose to clean generator Water can enter engine fuel system and cause problems In addition if water enters generator through cooling air slots some of the water will be retained in voi...

Страница 16: ...ling air slots and openings on generator are open and unobstructed Engine Storage See engine owner s manual for instructions Other Storage Tips To prevent gum from forming in fuel system or on essenti...

Страница 17: ...ad but bogs down when loads are connected 1 Short circuit in a connected load 2 Generator is overloaded 3 Shorted generator circuit 1 Disconnect shorted electrical load 2 See Don t Overload Generator...

Страница 18: ...18 BSPP Generator NOTES...

Страница 19: ...sed for commercial purposes are not warranted NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS STRATTON PRODUCTS SAVE YOUR PROOF OF PURCHASE RECEIPT IF YOU DO NOT PROVIDE PROOF OF TH...

Страница 20: ...e droit de changer d alt rer ou d am liorer le produit n importe quel moment sans avis pr alable Le Syst me de contr le de l mission du g n rateur est garanti pour des normes tablies par L Agence de p...

Страница 21: ...ugle ou vous blesser gravement Le liquide d lectrolyte de l accumulateur contient de l acide et est extr mement caustique Le contact avec le liquide de l accumulateur provoquera de graves br lures chi...

Страница 22: ...nchez toujours le c ble de bougie et placez le de fa on ce qu il ne soit pas en contact avec la bougie LORS DE TESTS D ALLUMAGE DU MOTEUR Utilisez un v rificateur de bougies d allumage approuv NE v ri...

Страница 23: ...arge est appliqu e Il faut cependant s assurer que l interrupteur est sur OFF lorsque vous mettez en route le moteur Interrupteur de starter Utilis lorsque vous faites un d marrage froid du moteur M t...

Страница 24: ...es Prise de verrouillage 120V 30 amp res Ensemble de roulettes Si certaines pi ces sont manquantes ou endommag es appelez le 1 800 743 4115 Installe la Roue la Trousse Les roues ont t con ues pour am...

Страница 25: ...nsultez les recommandations contenues dans le manuel d utilisation du moteur REMARQUE Le champ tournant du g n rateur est port par un roulement billes pr lubrifi et scell qui ne n cessite aucune lubri...

Страница 26: ...ient s accumuler et p n trer ou tre aspir s dans un difice qui pourrait tre occup Assurez vous que les gaz d chappement ne puissent entrer par une fen tre une porte une prise d a ration ou une autre o...

Страница 27: ...ctionnement du Contr le Automatique du Ralenti Cet interrupteur a pour but d am liorer grandement l conomie en carburant Lorsque cet interrupteur est en MARCHE ON le moteur ne marchera sa vitesse lev...

Страница 28: ...l hydrom tre G n ralement on consid re qu une batterie est charg e 100 lorsque la gravit sp cifique de son fluide mesur e par l hydrom tre est de 1 260 ou davantage FONCTIONNEMENT PAR TEMPS FROID Sou...

Страница 29: ...nctionner le moteur l ext rieur 11 Assurez vous que les gaz d chappement ne puissent entrer dans un espace restreint par une fen tre une porte une prise d a ration ou une autre ouverture 12 N envelopp...

Страница 30: ...prise de courant Figure 24 est prot g e contre les surtensions par un disjoncteur bipolaire de type GFCI Utilisez chaque prise de courant pour faire fonctionner les charges lectriques de 120 volts c...

Страница 31: ...n ratrice fonctionner sans charge durant 1 minute 2 Si le disjoncteur r ussit l essai il se peut que l quipement lectrique ou les rallonges soient d fectueux Remplacez l quipement lectrique ou les ra...

Страница 32: ...ur tourne r guli rement et les dispositifs branch s fonctionnent correctement 4 Branchez et mettez la charge suivante en marche 5 De nouveau laissez le g n rateur se stabiliser 6 R p tez les tapes 4 e...

Страница 33: ...moteur et causer des probl mes De plus si l eau entre par les fentes de refroidissement air une partie de l eau restera dans les creux et craquelures de l isolation du bobinage du rotor et du stator L...

Страница 34: ...rtes et non bouch es Remisage du Moteur Voir les instructions sur la mani re de remiser correctement le moteur dans le manuel de l utilisateur du moteur Autres Id es de Remisage Afin de pr venir l acc...

Страница 35: ...ont branch es 1 Court circuit dans une charge branch e 2 Le g n rateur est surcharg 3 Court circuit dans le g n rateur 1 D brancher la charge en court circuit 2 Voir Ne Pas Surcharger G n rateur 3 Con...

Страница 36: ...BSPP G n ratrice 36 REMARQUES...

Страница 37: ...S STRATTON IL N EST PAS N CESSAIRE DE L ENREGISTRER CONSERVEZ LE RE U COMME PREUVE D ACHAT SI LORS D UNE R CLAMATION DE GARANTIE VOUS NE POUVEZ PROUVER LA DATE INITIALE DE L ACHAT NOUS UTILISERONS LA...

Страница 38: ...orar el producto y este documento en cualquier momento sin previo aviso El Sistema de Control de Emisiones para este generador est garantizado para juegos est ndares por la Agencia de Protecci n Ambie...

Страница 39: ...os materiales ADVERTENCIA CUANDO A ADA COMBUSTIBLE O VAC E EL DEP SITO Apague el generador posici n OFF y d jelo enfriar al menos por 2 minutos antes de remover la tapa de la combustible Afloje la ta...

Страница 40: ...USTE O HAGA REPARACIONES A SU GENERADOR Siempre desconecte el alambre de la buj a y col quelo donde no pueda entrar en contacto con la buj a CUANDO PRUEBE LA BUJ A DEL MOTOR Utilice un comprobador de...

Страница 41: ...tamente disponible cu ndo llamar para la ayuda Silenciador Apagachispas El silenciador disminuye el ruido del motor y est equipado con una pantalla apagachispas Tanque del Combustible El tanque tiene...

Страница 42: ...fes de 30 Amperios Enchufes de 20 Amperios Juego de Ruedas Si cualquier parte falta o est da ada llame a la L nea de Ayuda del Generador al 1 800 743 4115 INSTALE EL JUEGO DE RUEDAS El juego de ruedas...

Страница 43: ...te cuando ste se esfuerce demasiado Consulte el manual del propietario del motor para conocer cu les son las recomendaciones al respecto NOTA El campo giratorio del generador se encuentra en un cojine...

Страница 44: ...estar ocupado Aseg rese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci n u otras aberturas en un espacio cerrado en el que puedan acumularse Figura 31 Teng...

Страница 45: ...rol de ralent en la posici n Off Desactivado 3 Deje que el motor funcione sin cargas por algunos minutos para estabilizar las temperaturas internas del motor y el generador 4 Sit e la v lvula de combu...

Страница 46: ...ne mientras la bater a se recarga 9 Apague el motor cuando la bater a se haya cargado NOTA Use un hidr metro para autom viles para probar el estado de carga y condici n de la bater a Siga cuidadosamen...

Страница 47: ...y mant ngalo en marcha en exteriores 11 Aseg rese de que los gases de escape no puedan entrar por ventanas puertas tomas de aire de ventilaci n u otras aberturas en un espacio cerrado en el que pueda...

Страница 48: ...a 120 Voltios 4 800 vatios de energ a 4 8 kW a 20 Amperios para 240 Voltios El enchufe est protegido contra sobrecargas por un disyuntor bipolar con detecci n de fallos de conexi n a tierra NUNCA inte...

Страница 49: ...cada recept culo para operar 120Voltios AC de fase sencilla de cargas de 60Hz que requieren hasta 2 400 vatios 2 4 kW a corrientes de 20 Amperios Use los juegos de cables que son calificados para car...

Страница 50: ...enerador sin cargas durante 1 minuto 2 Si la prueba del disyuntor es satisfactoria es probable que haya un fallo en el equipo el ctrico o en los cables alargadores Sustituya el equipo el ctrico y los...

Страница 51: ...funciona suavemente y el aparato conectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada car...

Страница 52: ...ndo otras substancias extra as sean visibles en su superficie exterior NOTA NO recomendamos el uso de mangueras de jard n para limpiar el generador El agua podr a introducirse en el sistema de combust...

Страница 53: ...evise que las ranuras para el aire de enfriamiento y las aperturas del generador se encuentren abiertas y despejadas Almacenando el Motor Consulte el manual del propietario del motor para las instrucc...

Страница 54: ...54 BSPP Generador NOTES...

Страница 55: ...ntectan cargas 1 Corto circuito en una de las cargas conectadas 2 El generador est sobrecarga 3 Circuito del generador en corto 1 Desconecte la carga el ctrica en corto 2 Vea No Sobrerecarque Generado...

Страница 56: ...ON PRODUCTS GUARDE SU RECIBO DE COMPRA SI NO APORTA LA PRUEBA DE LA FECHA DE COMPRA INICIAL SE UTILIZAR LA FECHA DE FABRICACI N DEL PRODUCTO PARA DETERMINAR EL PER ODO DE GARANT A ACERCA DE LA EQUIPO...

Отзывы: