Note: Only use SFP transceivers that meet or exceed the following standards:
EU: IEC/EN 60825-1, North America: FCC, CDRH
Note: SFPs will come pre-installed when a Fibre Channel card has been
purchased with your configuration.
The following multi-mode optical fibre cables are supported up to the lengths given:
Fibre Channel Speed
OM1
OM2
OM3
OM4
2Gb/s
150m
300m
500m
4Gb/s
70m
150m
380m
400m
8Gb/s
21m
50m
150m
190m
16Gb/s
15m
35m
100m
125m
32Gb/s
20m
70m
100m
Connect your host to a target port and your device (such as a tape drive) to an initiator port.
Note: By default WANrockIT units have the left hand port (Port A) as the
target port and the right hand port (Port B) as the initiator port.
When the multi-mode cables are inserted in to the SFP, a “click” should be heard.