PH44/PH80 
Quick Start Guide 

 

Action  

Instruction 

Activate Control 

Menu 

To activate control menu, do a long press on the [Reset] button until the System Health LED indicators (LED 9 and 10) are flashing 
in green. Do an immediate short press again to enter into the control menu. LED 1-4 flashes green indicating control menu is 
successfully triggered.  

Function Selection 

After successfully triggering the control menu, the corresponding 4 functions below can be toggled by doing short presses on the 
[Reset] button, this will be reflected on LED 1-4.  
 
1)Rollback to previous firmware  
2)Set Hub back to un-configured state  

3)Reset Hub to Factory Settings  
4)Go back to selection (1)  
 
Once the desired function is selected, simply do a long press and the selected LED will change from green to yellow indicating that 
the function desired is successfully executed. If there is no input selection for a period of time, the hub will return to the normal 
operation mode.  

Reboot 

To perform a reboot function, simply do a short press (3-5 seconds) on the [Reset] button.  

System Shutdown 

To perform a system shutdown, simply press the [Reset] button for more than 5 seconds and release.   
LED 9 will be flashing blue while LED 10 will be flashing green indicating a successful shutdown.  

 

 

 

 

 

 

 

 

 

 

 

Hub Status Description 

System Health LED Indicator 

LED 9 

LED 10 

Unconfigured Hub Mode  
(Please refer to the User Manual for configuration)  

Green blinking 

 

Green blinking 

 

Boot up  

Green Blinking  

 

Green  

 

Normal Operation Mode 

Green 

 

Green 

 

Re-Boot/ Shutdown 

Blue blinking  

 

Green 

 

Factory reset or firmware  rollback   

Yellow Blinking  

 

Yellow Blinking  

 

Factory reset or roll back failed 
(Manually power off and on hub to reboot)  

Blue blinking  

 

Blue blinking  

 

Network link missing  
(Check if Ethernet cable is connected or hub’s Wi-Fi is configured)  

Green  

 

Red 

 

Hub Temperature is above the threshold value 
(Alert notification will be sent to and Hub will shut down) 

Red Blinking  

 

Red Blinking  

 

What’s in the Box? 

24V DC Power Adaptor 

The Hub’s control menu cab be accessed through the [Reset] button located at the side of the hub to trigger certain actions:  

PH44/80 System Health LED Indicator  

PH44/PH80 Terminator  

 

Adaptor Model# 

Power Ratings 

PH44 

SSA-0601HE 

24VDC 2.5A 

PH80 

GST120A24-P1M 

24VDC 5.0A 

  

This device complies with part 15 of the FCC Rules. Operation is subject to the 
following two conditions:  
 
1)

 

This device may not cause harmful interference, and 

2)

 

This  device  must  accept  any  interference  received,  including  interference 
that may cause undesired operation. 

 
NOTE: This equipment has been tested and found to comply with the limits for 
a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are 
designed  to  provide  reasonable  protection  against  harmful  interference  in  a 
residential  installation.  This  equipment  generates,  uses  and  can  radiate  radio 
frequency  energy  and,  if  not  installed  and  used  in  accordance  with  the 
instructions,  may  cause  harmful  interference  to  radio  communications. 
However, there  is no  guarantee that interference  will not occur  in  a particular 

installation.  If  this  equipment  does  cause  harmful  interference  to  radio  or 
television reception, which can be determined by turning the equipment off and 
on, the user is encouraged to try to correct the interference by one or more of 
the following measures: 
 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

 

Connect  the  equipment  into  an  outlet  on  a  circuit  different  from  that  to 
which the receiver is connected. 

 

Consult the dealer or an experienced radio/TV technician for help. 
 

To  maintain  compliance  with  FCC’s  RF  exposure  guidelines,  at  least  (

To  be 

updated  based  on  MPE  report

)  cm  of  separation  distance  between  the  PanL 

Hub44 device and the user's body must be maintained at all times. 
 

The package includes a PH44/PH80 Hub, a 24V DC power adaptor and 4/8 
terminators  for  PH44/PH80  respectively.  The  power  plug  cable  is  not 
included in the box and may be packed outside the box separately.

 

FCC Statements 

Отзывы: