background image

PD70/PD70PLUS  
Quick Start Guide 

For  a  single  PD70/70PLUS  connection  to  a  PanL  Hub  port,  the  maximum 
length of the RJ45 8P8C cable is 100 meters. Connect the terminator provided 
in PanL Hub box to the unconnected PD70/70PLUS port.  
 

 
 
 
 
 
 
 
 
 
 
 
 

For multiple PD70/PD70PLUS connection to a single PanL Hub port, the 1st 
connection  to  PanL  Hub  and  the  subsequent  connections  in  between  the 
PD70/PD70PLUS  displays  must  not  exceed  50  meters  in  cable  length.  The 
total  combined  cable  lengths  must  not  exceed  100  meters.  Connect  the 
terminator  provided  in  PanL  Hub  box  to  the  last  unconnected 
PD70/PD70PLUS port. A maximum of two PD70/PD70PLUS can be connected 
to a single hub port as shown below:                            

 

 

 

1.

 

Mount  the  PD70/PD70PLUS  back  cover  either  on  an  Arlington  LV2* 
bracket  (Four  pieces  of  3.5mm  x  16  mm,  min.  length  12mm  self-
tapping screws are provided) or on a standard electrical junction box 
(86mm  x  86mm  x  40mm  screws;  min  length  12mm;  max.  length 
20mm- not provided). Two additional  on  wall screws are provided  to 
secure PD70PLUS. 

 

 

 

 

 

 

 
 
 
 
                       

 

 

 
 
 
 
 
 
 
 

2.

 

If connecting  multiple  PD70/PD70PLUS displays to a single PanL Hub 
port, set the ID switch. Refer to the section - 

ID Switch Configuration

 

for details. 

3.

 

Connect  RJ45  8P8C  cable  and  add  a  terminator.  Refer  to  the  section 

Display Installation

 for details. 

4.

 

Install the front panel on back cover and secure the panel. 

 

*Arlington LV2 low voltage mounting bracket and    electrical junction 
box are not part of the package. 

 

For multiple PD70/PD70PLUS connections to a single PanL Hub port, the ID 
switch at the back of the displays must be configured to be unique. Using a 
Philip head screw driver, set a unique number for each display between 

0-7 

(do not use 8- 9). 

For example, if connecting 2 PD70 / PD70PLUS to a PanL 

Hub port, you may set it as 

0 and 1

. Displays connected to different PanL 

Hub ports can share the same unique number.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Product Features 

  

PD70 

  PD70PLUS 

1

 

Buzzer  

Ambient Light Sensor

 - Automatic screen brightness control  

Reset Button 

Reserved for factory use 

Status indicator

 - Refer to the LED Status Indicator section for 

more details 

System  Indicator

  -  Refer to  application user guide  for  more 

details 

RFID Reader 

- Refer to RFID Reader section for more details 

 

Display Installation 

Wall Mounting 

ID Switch Configuration 

Please  visit 

http://panlshop.com/warranty

  or  scan  the 

QR 

code

 for warranty registration with the UUID and Product Key 

below:  

 

 

STICKER AREA 

 

RFID Reader (PD70PLUS only) 

The built in 13.56MHz RFID reader supports ISO/IEC 14443 A/MIFARE and 
NTAG. The internal transmitter is able to drive a reader antenna designed to 
communicate  with  ISO/IEC  14443  A/MIFARE  cards.  The  receiver  module 
provides  a  robust  and  efficient  implementation  for  demodulating  and 
decoding  signals  from  ISO/IEC  14443  A/MIFARE  compatible  cards  and 
transponders.  The  digital  module  manages  the  complete  ISO/IEC  14443 
framing and error detection (parity and CRC) functionality. 

PD70 

Electrical  

Junction Box 

Arlington LV2 

PD70PLUS 

PD70 

PD70PLUS 

Отзывы: