4.31
MACRO
Execute a single command from a macro register.
Encoding
31 24 23 1 0
0x25
Reserved
m
Parameters
m
Macro register to read. Value 0 means the FT800 will fetch the command
from REG_MACRO_0 to execute. Value 1 means the FT800 will fetch the
command from REG_MACRO_1 to execute. The content of REG_MACRO_0 or
REG_MACRO_1 shall be a valid display list command, otherwise the behavior
is undefined.
Graphics context
None
See also