BrickElectric Ethernet Relay 

BEM106 

Excellent network building block   

 

 

 

Features   

 

WEB control 

 

Modbus-TCP 

 

X-Connect 

 

Hardware Reset 

 

5 - 24 VDC power supply   

 

EasyBus - simple solution 

 

Android App 

 

LAN mode 

 

DHCP - Plug and play 

 

Internet Control 

 

Password Protection 

Introduction   

BEM106 is an Wide Supply Input, Ethernet Remote Relay Module, with 8 output channels, and 

provide  with  both  enclosed  and  open  type  housing.  Its  Ethernet  connector  provides  10/100baseT 

interface. 

 

It supports EasyBus-TCP, HTTP control, Modbus-TCP and Internet control protocols, suitable 

for being used with servers, computers, mobiles, routers, etc., to provide remote control and monitor. 

You can also define the port number for HTTP by yourself, to realize Router Port Forwarding. 

 

With DHCP functions, it doesn't need to make any settings anymore in field. So 

just plug and 

play

, power it on and then enjoy your remote control. 

 

BEM106  is  a  new  generation  product  with  more  functions  and  higher  stability.  Control  mode 

"toggle" and "automatic cycle operation" are provided additionally. 

 

 

 

Содержание BEM106

Страница 1: ...s Ethernet connector provides 10 100baseT interface It supports EasyBus TCP HTTP control Modbus TCP and Internet control protocols suitable for being used with servers computers mobiles routers etc to...

Страница 2: ...Communications 9 4 2 Save Parameters 9 4 3 Reboot 9 4 3 DHCP Function 10 4 4 Static IP Address 10 4 5 Relay outputs control 11 4 6 Password protection 16 4 7 Http port setting 17 4 8 Hardware reset b...

Страница 3: ...www BrickElectric com 1 Device Overview 1 1 General Ratings Power Consumption 5W max Operation Temperature 30 to 85 Module Size 150mmx80mmx20mm Weight 1 2 Connection Diagram Fig 1 1...

Страница 4: ...C 10A 125VAC 10A 24VDC 10A 12VDC 10A 2 2 Default Software Settings Default Settings IP Setting IP address 192 168 1 105 Subnet Mask 255 255 255 0 Gateway 192 168 1 1 DHCP disable Latest Firmware Versi...

Страница 5: ...rk by minimum steps For more information please refer to later chapters 3 1 HTTP Mode 1 Connect BEM106 with your routers or computer via a standard Ethernet cable And then power it on with 5 24VDC pow...

Страница 6: ...2 2 Open any TCP test tool if you don t have any or you don t know what a TCP test tool is you can use BE Manager it is within our software package Open it and see the following Fig 1 2 Fig 1 2 3 Cli...

Страница 7: ...www BrickElectric com Fig 1 3...

Страница 8: ...1 1 at page 2 2 Open Hello Brick app for android at any android phone register a user and then have fun with Internet control No other need at relay module is necessary 3 If you need online help or n...

Страница 9: ...delivered together with module package 4 2 Save Parameters After power cycle BEM106 will lose its parameter modifications if you don t actively require it to save modified parameters into internal no...

Страница 10: ...Assuming module current IP Address is 192 168 1 105 for all the following commands Enable Disable DHCP Note modification only effective after parameter saving and module reboot To Enable DHCP Web acce...

Страница 11: ...on only effective after parameter saving and module reboot To set static Gateway Address to 192 168 2 1 Web access URL http 192 168 1 105 gateway 192 168 2 1 Socket command text gateway 192 168 2 1 Se...

Страница 12: ...ands No timing features included Switches To switch off ch1 output Web access URL http 192 168 1 105 k01 0 Socket command text k01 0 To switch on ch1 output Web access URL http 192 168 1 105 k01 1 Soc...

Страница 13: ...ommands and wait for a predefined time period then automatically switches to opposite status Switches To pulse off ch1 output you can input by require web access Web access URL http 192 168 1 105 k01...

Страница 14: ...supports from 1ms to 4294967295 second K0xT1 is needed to be set for time value and K0xU1 is need to be set for timer value unit Default value for K0xT1 is 1000 and default unit for K0xU1 is ms To se...

Страница 15: ...ized timer for relay cycle outputs timer T1 and T2 are used and need to be set Each relay channel has two independent timers K0xT1 and K0xT2 time period supports from 1ms to 4294967295 second K0xT1 K0...

Страница 16: ...tput status for feedback control Module will return the current status in web content or socket text depending on how do you send the command To read relay ch1 current status Web access URL http 192 1...

Страница 17: ...r port forwarding or any other reasons For example you can force your web browser to access http content at port 8080 to do so you need to enter http url 8080 This module is able to customize http acc...

Страница 18: ...e and try to download latest firmware from Internet Please connect to internet when you do this operation 4 9 Identification customized information When more than one modules are installed in the fiel...

Страница 19: ...Read device firmware version you can read device firmware version by communication for the purpose of better identification the device or diagnosis To read device firmware version Web access URL http...

Страница 20: ...ra 132 0 EasyBus Server Local Port Number This parameters setup the local listening port number at relay module To read relay module EasyBus Server Local Port Number Web access URL http 192 168 1 105...

Страница 21: ...te server port number for relay module to connect To read relay module EasyBus Client Remote Port Number Web access URL http 192 168 1 105 getpara 130 1 Socket command text getpara 130 1 To set relay...

Страница 22: ...source for the entire network but if you really want to keep a long connection between relay module and server this behavior will create troubles Another problem is when the connection is accidently b...

Страница 23: ...he higher the value of this parameters the longer the server un response time will be allowed In good network environment this is recommended so it will save the traffic in total For example setpara 1...

Страница 24: ...o ping mode select default is fixed IP mode 2 Configure Fixed IP or Domain Name default is your gateway IP 3 Configure programmable reboot sequence default is no action 4 Set time between pings defaul...

Страница 25: ...nnel 1 Web access URL Write http 192 168 1 105 setpara 101 192 setpara 102 168 setpara 103 1 setpara 104 100 Read http 192 168 1 105 getpara 101 192 getpara 102 168 getpara 103 1 getpara 104 100 Socke...

Страница 26: ...ase of remote IP device becomes unresponsive auto ping function will run a pre set reboot sequence to make a customized reboot action according to your application For this function the following comm...

Страница 27: ...65535 seconds Normally 60 seconds should be useful for most applications To setup time you need to set 2 parameters time unit and time Auto Ping Channel 1 1 To set time unit to millisecond setpara 45...

Страница 28: ...xt Write setpara 158 5 Read getpara 158 1 6 Delay time after reboot After auto ping detected an external controller unresponsive failure and running a reboot sequence it is naturally necessary that th...

Страница 29: ...ping function please make sure your every other setting is finished so it can work correctly If you save settings after auto ping start when power on the device auto ping will automatically start aga...

Страница 30: ...output module When one input is mapped to one or more outputs then if this input is triggered all the outputs that it mapped will also be triggered immediately 6 1 X Connect Map Setting Each BEM Seri...

Страница 31: ...ct 1 8 105 4 VWSL4 X Connect CH4 input select 1 8 106 5 VWSL5 X Connect CH5 input select 1 8 107 6 VWSL6 X Connect CH6 input select 1 8 108 7 VWSL7 X Connect CH7 input select 1 8 109 8 VWSL8 X Connect...

Страница 32: ...61 8 VWSIP81 X Connect CH8 target IP 1 0 255 162 8 VWSIP82 X Connect CH8 target IP 2 0 255 163 8 VWSIP83 X Connect CH8 target IP 3 0 255 164 8 VWSIP84 X Connect CH8 target IP 4 0 255 165 9 VWSIP91 X C...

Страница 33: ...TCP frame structure or create your own Modbus TCP program here are the detailed message frame for each command To switch on relay channel 1 output Ethernet frame 0x05 0x00 0x00 0xFF 0x00 To switch off...

Страница 34: ...witch off relay channel 6 output Ethernet frame 0x05 0x00 0x05 0x00 0x00 To switch on relay channel 7 output Ethernet frame 0x05 0x00 0x06 0xFF 0x00 To switch off relay channel 7 output Ethernet frame...

Страница 35: ...e old fashioned and very detailed industry automation communication protocol before they can really start to do anything How to send a correct switch command Example switch on relay channel 1 K01 1 Ex...

Страница 36: ...192 range 0 255 011 SIP2 module IP address 2 default value 168 range 0 255 012 SIP3 module IP address 3 default value 1 range 0 255 013 SIP4 module IP address 4 default value 105 range 0 255 014 Reser...

Страница 37: ...27 Reserved parameter default value range 028 Reserved parameter default value range 029 K1U1 Relay K1 timer T1 unit selector 0 ms 1 second default value 0 range 0 1 030 K1U2 Relay K1 timer T2 unit se...

Страница 38: ...ms 1 second default value 0 range 0 1 040 K6U2 Relay K6 timer T2 unit selector 0 ms 1 second default value 0 range 0 1 041 K7U1 Relay K7 timer T1 unit selector 0 ms 1 second default value 0 range 0 1...

Страница 39: ...range 054 Reserved parameter default value range 055 Reserved parameter default value range 056 Reserved parameter default value range 057 Reserved parameter default value range 058 Reserved paramete...

Страница 40: ...1000 range 0 65535 070 K3T2 Relay K3 timer T2 value default value 1000 range 0 65535 071 K4T1 Relay K4 timer T1 value default value 1000 range 0 65535 072 K4T2 Relay K4 timer T2 value default value 1...

Страница 41: ...r default value range 083 Reserved parameter default value range 084 Reserved parameter default value range 085 Reserved parameter default value range 086 Reserved parameter default value range 087 Re...

Страница 42: ...P Device model type default value 105 range 100 DEVSN Device serial number default value range 101 PIP1 1 Ping monitor 1 IP address 1 default value 192 range 0 255 102 PIP1 2 Ping monitor 1 IP address...

Страница 43: ...d parameter default value range 113 Reserved parameter default value range 114 Reserved parameter default value range 116 Reserved parameter default value range 117 Reserved parameter default value ra...

Страница 44: ...rameter default value range 130 Reserved parameter default value range 131 Reserved parameter default value range 132 Reserved parameter default value range 133 PNAME1 Ping monitor 1 domain name max 5...

Страница 45: ...AIT 5 K02 0 range 143 Reserved parameter default value range 144 Reserved parameter default value range 145 Reserved parameter default value range 146 Reserved parameter default value range 147 Reserv...

Страница 46: ...r 2 max allowed no response failure times before reboot default value 3 range 0 65535 159 Reserved parameter default value range 160 Reserved parameter default value range 161 Reserved parameter defau...

Страница 47: ...lector after reboot 0 ms 1 second default value 0 range 0 1 174 PDU2 Ping monitor 2 delay timer unit selector after reboot 0 ms 1 second default value 0 range 0 1 175 Reserved parameter default value...

Страница 48: ...ult value 0 range 0 1 183 Reserved parameter default value range 184 Reserved parameter default value range 185 Reserved parameter default value range 186 Reserved parameter default value range 187 Re...

Страница 49: ...brickelectric com Skype Online Support 86 182 1730 3961 WhatsApp Online Support 86 182 1730 3961 Call Us 86 182 1730 3961 If you have any questions or any customized software hardware requirement plea...

Отзывы: