background image

 

50 Winter Crt

 

Whitby, ON. L1N-8Y1

 

 

(905)-666-0200

 

 

Fax (905)-665-1848

 

 

www.winecellarcreations.com 

 

 

 

WKS 2200 SERIES 

 

--INSTALLATION INSTRUCTIONS— 

 
 

Thank you for choosing a 

BREEZAIRE 

cooling unit. We believe our products are the 

best on the market and will provide many years of trouble-free service. 

 

Please take a few minutes and read the entire instruction booklet before beginning the installation. 

 
 

 

Before removing the cooling unit from the box, please inspect for damage which 

might have occurred during shipping. If damage is found, notify the shipper 

immediately and file a claim. BREEZAIRE is not responsible for any damages 

during shipping.

 

 

 
 
MODEL

___________________.

SERIAL NUMBER

__________________. 

 

 
 
INSTALLED BY_____________________________. DATE____________________. 

 
 
 
 

BREEZAIRE 

Products Company - 8610 Production Avenue - San Diego, CA USA 92121 - (858) 566-7465 

 

Содержание WKS-2200 Series

Страница 1: ...d the entire instruction booklet before beginning the installation Before removing the cooling unit from the box please inspect for damage which might have occurred during shipping If damage is found notify the shipper immediately and file a claim BREEZAIRE is not responsible for any damages during shipping MODEL___________________ SERIAL NUMBER__________________ INSTALLED BY______________________...

Страница 2: ...EEZAIRE dealer for assistance in choosing the correct unit BREEZAIRE units are not warranted to cool a specific enclosure All interior walls and floor should have a vapor barrier and a minimum of R 11 insulation All exterior wall s insulation values should be a minimum of R 19 The ceiling should have vapor barrier and a minimum of R 19 insulation The vapor barrier should be installed on the warm s...

Страница 3: ...ble flooding and shaded from direct sun light Remove the screws and the cover F Plumbing the system The two units are connected by a 1 4 inch liquid line copper tube and a 3 8 inch suction line copper tube The line set should have a minimum linear length not less than 35 ft and a maximum linear length no longer than 100 ft for each line Reduce the line set length by 10 feet for every hard 90 bend ...

Страница 4: ...cted and vacuumed to prevent any air blockage The condenser coil in the condensing unit is located out side the enclosure Use a vacuum and brush attachment to remove the lint or dirt that may reside between the aluminum fins If the condenser coil becomes blocked preventing proper air flow the unit will over heat causing a loss in cooling efficiency and will result in failure of the unit not covere...

Страница 5: ...from the unit One way of discovering gross air leaks is to stand inside the enclosure with the lights off allow your eyes to adapt to the dark and look for light showing through cracks in the walls or around the door Because of the temperature difference between the inside and outside very small cracks can allow large amounts of outside air into the enclosure Please be aware that moisture can pass...

Страница 6: ...ed to BREEZAIRE in a condition that allows testing of the component and if that component is determined defective BREEZAIRE will refund the customer the cost of the component and freight What BREEZAIRE will NOT pay for 1 Installation or removal of the unit component 2 Handling or packaging of the unit component 3 Component repairs performed by anyone other than a BREEZAIRE authorized repair facili...