Breezaire WKS 2200 Series Скачать руководство пользователя страница 1

          8610 Production Avenue 

l

  San Diego, California 92121 

l

  (858) 566-7465 

l

  Fax (858) 566-1943 

l

  WWW.BREEZAIRE.COM

BREEZAIRE

 Products Company - 8610 Production Avenue - San Diego, CA USA 92121 - (858) 566-7465

WKS 2200 SERIES

(USA only)

--INSTALLATION INSTRUCTIONS--

Thank you for choosing a 

BREEZAIRE

 

cooling unit.  We believe our products are the best

on the market and will provide many years of trouble free service.

Please take a few minutes and read this entire instruction before beginning the installation.

MODEL_

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

_  SERIAL NUMBER_

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

_

INSTALLED BY  _

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

_  DATE_

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

__

_

While great effort has been made to provide accurate guidelines, 

BREEZAIRE

 cannot warrant its units to properly cool a particular enclosure.  Customers are cautioned that enclosure

construction, unit location and many other factors can affect the operation and performance of the unit.  Therefore the suitability of  the unit for a specific enclosure or application must
be determined by the customer and cannot be warranted by 

BREEZAIRE.

Before removing the cooling unit from the box, please inspect for damage which might have been

incurred during shipping.  If damage is found, notify the Freight Company immediately.

BREEZAIRE

 

is not responsible for any damages incurred during shipping.

Содержание WKS 2200 Series

Страница 1: ...INSTALLED BY _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ DATE_ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ While great effort has been made to provide accurate guidelines BREEZAIRE cannot warrant its units to properly cool a particular enclosure Customers are cautioned that enclosure construction unit location and many other factors can affec...

Страница 2: ... not warranted to cool a specific enclosure All interior walls and floor should have a vapor barrier and a minimum of R 11 insulation All exterior wall s insulation values should be a minimum of R 19 The ceiling should have vapor barrier and a minimum of R 19 insulation The vapor barrier should be installed on the warm side of the insulation There should be no glass windows or doors F All joints d...

Страница 3: ...ndensing unit on a solid foundation in a location with at least 1 foot of clearance on all sides and the warm exhausting air to be unobstructed for at least 3 feet Figure 2 This location should be an area where the temperature is not higher than 85 F or lower than 20 F The condensing unit should be elevated to avoid any possible flooding and shaded from direct sun light Remove the screws and the c...

Страница 4: ...t was charged The final set of gauge readings should be taken when the wine storage area is at 55 F and the condenser area approximately 85 F OPERATION On initial start up the cooling unit will reduce the temperature of the enclosure slowly The unit may run constantly or cycle off for short periods The time required to reach the desired temperature will vary depending on the enclosure construction...

Страница 5: ...is located in a confined area with poor ventilation the unit will not be able to reject the heat it is removing from the enclosure and a malfunctioning unit will be suspected Obstruction to the free flow of fresh air into or out of the condensing unit for any reason can cause the unit to heat rather than cool the enclosure Proper sealing of the enclosure through the use of a vapor barrier and weat...

Страница 6: ...S 2200 Condenser Figure 2 14 10 12 3 8 OD DRAIN TUBE 1 4 LIQUID LINE 3 8 SUCTION LINE 110V ELECTRICAL CORD EVAPORATOR INTAKE EVAPORATOR OUTLET THERMOSTAT CONDENSER OUTLET CONDENSER INTAKE FAN COIL UNIT CONDENSING UNIT FIGURE 1 FIGURE 2 A B C A C B 3 8 SUCTION LINE 1 4 LIQUID LINE ELECTRICAL WIRING ...