5. Attach enough piping to penetrate and extend at least
6” beyond exterior walls. An 8-foot vertical pipe run
is suggested where possible to reduce the possibility
of smoke spillage in the event of a loss of negative
pressure.
6. Attach cap and seal outside wall thimbles with non-
hardening waterproof mastic.
7. Termination should not be located so that hot exhaust
gases can ignite trees, shrubs, or grasses or be a hazard
to children. Exhaust gases can reach temperatures of
500ºF and cause serious burns if touched.
VERTICAL ROOF VENT
WALL STRAP
SEE VENT
MANUFACTURER
FOR NUMBER
AND SPACING
6” MIN.
CLEARANCE
TO ANY
COMBUSTIBLE
SURFACE
WALL THIMBLE
L-VENT
ADAPTER
CLEAN-OUT
TEE A 90
DEGREE
ELBOW
MAY ALSO
BE USED
6” MIN.
CLEARANCE
Locate terminations: a) not less than 3 feet above any forced
air inlet located within 10 feet; b) not less than 4 feet below
or horizontally from, or one foot above, any door, window
or gravity air inlet into any building; c) not less than two feet
from an adjacent building and not less than 7 feet above
grade when located adjacent to a public walkway. Mobile
home installations must use a spark arrester.
B. VERTICALLY WITH NEW CHIMNEY SYSTEM)
3” MIN
CLEARANCE TO
COMBUSTIBLES
ATTIC
INSULATION
SHIELD
VERTICAL
ROOF VENT
12” MIN. CLEARANCE TO ROOF
3” MIN
CLEARANCE TO
COMBUSTIBLES
L-VENT
ADAPTER
3” MIN
CLEARANCE TO
COMBUSTIBLES
ATTIC
INSULATION
SHIELD
VERTICAL
ROOF VENT
12” MIN. CLEARANCE TO ROOF
PIPE ADAPTER
VERTICAL
INSTALL KIT
3” MIN
CLEARANCE TO
COMBUSTIBLES
INSTALLATION