background image

Thank you for purchasing the Breckwell Pellet Burning Stove. You are now prepared to burn 

wood in the most efficient, convenient way possible. To achieve the safest, most efficient and 

most enjoyable performance from your stove, you must do three things: 1) Install it properly; 

2) Operate it correctly; and 3) Maintain it regularly. The purpose of this manual is to help you 

do all three. 

 

PLEASE read this entire manual before installation and use of this pellet fuel-burning 
room heater. Failure to follow these instructions could result in property damage, 
bodily injury or even death. 
 
Keep this manual handy for future reference. 

 
This stove has been independently tested to ASTM E1509-95 Standard Specification for 
Room Heaters, Pellet Fuel Burning Type 1, UL 1482-1998 Standard for Solid Fuel Room 
Heaters, Oregon Administrative Rules for Mobile Homes (814-23-900 through 814-23-909) 
and Installation as a Stove Heater. 
 
This pellet stove, when installed, must be electrically grounded in accordance with local 
codes, or in the absence of local codes, with the 

National Electrical Code, ANSI/NFPA 70

 
This appliance is designed specifically for use only with pelletized wood. It is designed for 
residential installation according to current national and local building codes as a freestanding 
room heater. It is also approved as a mobile home heater which is designed for connection to 
an outside combustion air source. 
 
The stove will not operate using natural draft or without a power source for the blower 
systems and fuel feed system and must not be burned with any type of coal (see 

PROPER 

FUEL).

 

 
This stove is designed to provide the optimum proportions of fuel and air to the fire in order to 
burn free of smoke and soot. Any blockage of the air supply to or from the stove will seriously 
degrade its performance and will be evidenced by a smoking exhaust and a sooting window. 
For best operation the ash content of the pellet fuel should be less than 1% and the calorific 
value approximately 8200 BTU/LB. Avoid high ash content fuels because this will rapidly fill 
up the burn pot and eventually cut off the combustion air supply. 
 
Commercial and industrial installations of Breckwell Pellet Stoves should not be used since 
operational control is often not well managed in these settings.

INTRODUCTION 

IMPORTANT INFORMATION 

 
Model: _____The Big E  _____________ 
Style: ____________________________ 
Serial Number:_____________________ 
Purchase Date: ____________________ 
Purchased From:___________________ 
 

 

      ___________________ 

 

 

      ___________________ 

MAIL YOUR WARRANTY CARD TODAY 

To receive full warranty coverage, you will 
need to show evidence of the date you 
purchased your stove. We suggest that 
you attach your sales invoice to this page, 
and fill in the form on the left, so that you 
will have all the information you need in 
one place should the need for service or 
information occur. 

Содержание Big E SP1000PB

Страница 1: ...For your safety follow the installation directions Contact local building or fire officials about restrictions and installation inspection requirements in your area PLEASE read this entire manual bef...

Страница 2: ...hich is designed for connection to an outside combustion air source The stove will not operate using natural draft or without a power source for the blower systems and fuel feed system and must not be...

Страница 3: ...out air conditioning or in an area where direct sunlight can shine on the unit it is possible this can cause the temperature of the stove to rise to operational levels one of the sensors could then ma...

Страница 4: ...g Door 12 Room Air Fan 12 Re Starting a Warm Stove 13 If Stove Runs Out Of Pellets 13 Refueling 13 Breckwell Maintenance Tool 13 Shutdown Procedure 13 Safety Features 13 Optional Thermostat 14 Thermos...

Страница 5: ...t be placed on a continuous grouted joints noncombustible material such as ceramic tile cement board brick 3 8 millboard or equivalent or other approved or listed material suited for floor protection...

Страница 6: ...d the stove WHEN OUTSIDE AIR IS NOT USED If outside air is not used it is important that combustion air is easily available to the air inlet A closeable outside air register can be used in tightly ins...

Страница 7: ...ent refer to figure 3 3 Always maintain 3 clearance from combustible materials 4 Install L Vent wall thimble per L Vent manufacturer s instructions 5 Attach enough piping to penetrate and extend at le...

Страница 8: ...ester C VERTICALLY INTO EXISTING CHIMNEY SYSTEM Adapters are available to adapt from 3 L Vent to 6 or 8 Class A chimney Figure 7 As an alternative 3 or 4 L Vent can be run inside existing chimney to t...

Страница 9: ...nnect the horizontal pipe by pushing it through the hole in the masonry and lining it up with the branch in the tee Push the pipe into the tee while twisting it to lock it into the tee 7 If desired on...

Страница 10: ...sher to penetrate paint or protective coating to ensure grounding The Breckwell Big E must be securely fastened to the floor of the mobile home through the two holes in the rear of the stove using 2 l...

Страница 11: ...n to its original setting based on the Heat Level Advance setting d RESET TRIM Different size and quality pellet fuel may require adjustment of the 1 feed setting on the Heat Level Advance bar graph T...

Страница 12: ...eckwell approved burnpot NOTE During the first few fires your stove will emit an odor as the high temperature paint cures or becomes seasoned to the metal Maintaining smaller fires will minimize this...

Страница 13: ...om of the hopper b Scrape ashes from burnpot SHUTDOWN PROCEDURE Turning your Breckwell stove off is a matter of pressing the On Off control panel switch The red light will go out The blowers will cont...

Страница 14: ...tion of this owner s manual HIGH LOW THERMOSTAT MODE When engaged in this mode the stove will automatically switch between two settings When warm enough it will switch to the 1 or low setting The room...

Страница 15: ...switch on the control panel g KEEP ALL LOOSE OR MOVEABLE HOUSEHOLD COMBUSTIBLES SUCH AS FURNITURE DRAPES TOYS ETC AT LEAST THREE FEET FROM THE OPERATING STOVE h Maintain proper ventilation It is impor...

Страница 16: ...ight up see Figure 16 d Empty ashes from the inner section and scrape with cleaning tool make sure holes are not plugged e Vacuum to remove ashes from the burn chamber interior and the burnpot shell W...

Страница 17: ...LIAR WITH HOW ASHES AND CREOSOTE ACCUMULATE WITH YOUR OPERATING PRACTICES Use the small wire brush to also clean the inside of the chamber walls above the access doors BLOWERS DANGER RISK OF ELECTRIC...

Страница 18: ...th a brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professio...

Страница 19: ...der the burnpot make sure the slider plate is in place to seal off the firebox floor 4 Vent pipe is incorrectly installed Check to make sure vent pipe installation meets criteria in owner s manual 5 T...

Страница 20: ...the auger tube for signs of damage such as burrs rough spots or grooves cut into the metal that could have caused a jam 7 The auger motor has failed Remove the auger motor from the auger shaft and tr...

Страница 21: ...r Check the voltage going to the igniter during startup It should be a full current If the voltage is lower than full current check the wiring If the wiring checks out good the board is bad SMOKE SMEL...

Страница 22: ...e the auger shaft inspection plate in the hopper so that you can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing...

Страница 23: ...ght at each setting after the stove has completed the startup cycle Make sure the times match the auger timing chart If the auger motor runs constantly the board is bad 8 Combustion blower is not spin...

Страница 24: ...being used and what setting No other types of fuel have been approved for Breckwell pellet stoves If there are signs of other types of fuel being used advise the consumer to stop using them immediatel...

Страница 25: ...FIGURE 21 ELECTRICAL DIAGRAM 25...

Страница 26: ...Hose C M 340 T Auger Motor C E 017 Breckwell Maintenance Tool A TOOL 96 Burnpot A S BURNPOT Circuit Board Control Panel C E 401 Combustion Blower A E 027 Convection Blower A E 033 Door Gasket C G 050...

Страница 27: ...fy the nearest Authorized Breckwell Dealer Provide your name address phone number serial number and model number of the stove date of purchase name and address of installer and as much information as...

Отзывы: