RE-STARTING A WARM STOVE 

 

If the stove has been shut off, and you want to re-start it while it is still warm, the “on/off” button must be held down for 2 seconds. 

 

IF STOVE RUNS OUT OF PELLETS

 

 
The fire goes out and the auger motor and blowers will run until the stove cools. This will take 30 to 45 minutes. 
After the stove components stop running the “On/Off” and the BAR GRAPH lights stay on for 10 minutes. 
After the 10 minutes the “3” light on the bar graph will flash and the “On/Off” light will go off. 
To restart, refill hopper and press “Fuel Feed” button until pellets begin to fall into burnpot. Press “On/Off” button. 
 

REFUELING

 

 
We recommend that you not let the hopper drop below ¼ full.

  

 

KEEP HOPPER LID CLOSED AT ALL TIMES EXCEPT WHEN REFILLING. DO NOT OVERFILL HOPPER.  
 

BRECKWELL MAINTENANCE TOOL

 

 
A tool has been provided to help with the following functions: 

 

a. 

Stirring pellets in hopper

 – unlike liquids in a tank, pellets do not drain evenly into the auger. Bridging across the opening can occur. 

Pellets can hang up on the sides of the hopper. Occasionally “stirring” the hopper can help. 

 

NOTE: 

To help prevent bridging of pellets, common wax paper can be rubbed on the sidewalls and bottom of the hopper. 

 
b. 

Scrape ashes from burnpot. 

 

SHUTDOWN PROCEDURE 

 
Turning your Breckwell stove off is a matter of pressing the “On/Off” control panel switch. The red light will go out. The blowers will continue 
to operate until internal firebox temperatures have fallen to a preset level. 
 

SAFETY FEATURES 

 
a. 

Your stove is equipped with a high temperature thermodisc. This safety switch has two functions. 

 

1. 

To recognize an overheat situation in the stove and shut down the fuel feed or auger system. 

 
2. 

In case of a malfunctioning convection blower, the high-temperature thermodisc will automatically shut down the auger, preventing 
the stove from overheating. 

 

NOTE: 

On some units, once tripped, like a circuit breaker, the reset button will have to be pushed before restarting your stove. On other 

units the thermodisk has no reset button and will reset itself once the stove has cooled. The manufacturer recommends that you call your 
dealer if this occurs as this may indicate a more serious problem. A service call may be required. 
 
b. 

If the combustion blower fails, an air pressure switch will automatically shut down the auger. 

 

NOTE:

 Opening the stove door for more than 30 seconds during operation will cause enough pressure change to activate the air switch, 

shutting the fuel feed off. Close the door and press “On/Off” button to continue operation of your stove. 

FIGURE 13 

OPERATION 

13 

Содержание Big E SP1000PB

Страница 1: ...For your safety follow the installation directions Contact local building or fire officials about restrictions and installation inspection requirements in your area PLEASE read this entire manual bef...

Страница 2: ...hich is designed for connection to an outside combustion air source The stove will not operate using natural draft or without a power source for the blower systems and fuel feed system and must not be...

Страница 3: ...out air conditioning or in an area where direct sunlight can shine on the unit it is possible this can cause the temperature of the stove to rise to operational levels one of the sensors could then ma...

Страница 4: ...g Door 12 Room Air Fan 12 Re Starting a Warm Stove 13 If Stove Runs Out Of Pellets 13 Refueling 13 Breckwell Maintenance Tool 13 Shutdown Procedure 13 Safety Features 13 Optional Thermostat 14 Thermos...

Страница 5: ...t be placed on a continuous grouted joints noncombustible material such as ceramic tile cement board brick 3 8 millboard or equivalent or other approved or listed material suited for floor protection...

Страница 6: ...d the stove WHEN OUTSIDE AIR IS NOT USED If outside air is not used it is important that combustion air is easily available to the air inlet A closeable outside air register can be used in tightly ins...

Страница 7: ...ent refer to figure 3 3 Always maintain 3 clearance from combustible materials 4 Install L Vent wall thimble per L Vent manufacturer s instructions 5 Attach enough piping to penetrate and extend at le...

Страница 8: ...ester C VERTICALLY INTO EXISTING CHIMNEY SYSTEM Adapters are available to adapt from 3 L Vent to 6 or 8 Class A chimney Figure 7 As an alternative 3 or 4 L Vent can be run inside existing chimney to t...

Страница 9: ...nnect the horizontal pipe by pushing it through the hole in the masonry and lining it up with the branch in the tee Push the pipe into the tee while twisting it to lock it into the tee 7 If desired on...

Страница 10: ...sher to penetrate paint or protective coating to ensure grounding The Breckwell Big E must be securely fastened to the floor of the mobile home through the two holes in the rear of the stove using 2 l...

Страница 11: ...n to its original setting based on the Heat Level Advance setting d RESET TRIM Different size and quality pellet fuel may require adjustment of the 1 feed setting on the Heat Level Advance bar graph T...

Страница 12: ...eckwell approved burnpot NOTE During the first few fires your stove will emit an odor as the high temperature paint cures or becomes seasoned to the metal Maintaining smaller fires will minimize this...

Страница 13: ...om of the hopper b Scrape ashes from burnpot SHUTDOWN PROCEDURE Turning your Breckwell stove off is a matter of pressing the On Off control panel switch The red light will go out The blowers will cont...

Страница 14: ...tion of this owner s manual HIGH LOW THERMOSTAT MODE When engaged in this mode the stove will automatically switch between two settings When warm enough it will switch to the 1 or low setting The room...

Страница 15: ...switch on the control panel g KEEP ALL LOOSE OR MOVEABLE HOUSEHOLD COMBUSTIBLES SUCH AS FURNITURE DRAPES TOYS ETC AT LEAST THREE FEET FROM THE OPERATING STOVE h Maintain proper ventilation It is impor...

Страница 16: ...ight up see Figure 16 d Empty ashes from the inner section and scrape with cleaning tool make sure holes are not plugged e Vacuum to remove ashes from the burn chamber interior and the burnpot shell W...

Страница 17: ...LIAR WITH HOW ASHES AND CREOSOTE ACCUMULATE WITH YOUR OPERATING PRACTICES Use the small wire brush to also clean the inside of the chamber walls above the access doors BLOWERS DANGER RISK OF ELECTRIC...

Страница 18: ...th a brush specifically designed for the type of chimney in use A qualified chimney sweep can perform this service It is also recommended that before each heating season the entire system be professio...

Страница 19: ...der the burnpot make sure the slider plate is in place to seal off the firebox floor 4 Vent pipe is incorrectly installed Check to make sure vent pipe installation meets criteria in owner s manual 5 T...

Страница 20: ...the auger tube for signs of damage such as burrs rough spots or grooves cut into the metal that could have caused a jam 7 The auger motor has failed Remove the auger motor from the auger shaft and tr...

Страница 21: ...r Check the voltage going to the igniter during startup It should be a full current If the voltage is lower than full current check the wiring If the wiring checks out good the board is bad SMOKE SMEL...

Страница 22: ...e the auger shaft inspection plate in the hopper so that you can see the auger shaft Gently lift the auger shaft straight up so that the end of the auger shaft comes up out of the bottom auger bushing...

Страница 23: ...ght at each setting after the stove has completed the startup cycle Make sure the times match the auger timing chart If the auger motor runs constantly the board is bad 8 Combustion blower is not spin...

Страница 24: ...being used and what setting No other types of fuel have been approved for Breckwell pellet stoves If there are signs of other types of fuel being used advise the consumer to stop using them immediatel...

Страница 25: ...FIGURE 21 ELECTRICAL DIAGRAM 25...

Страница 26: ...Hose C M 340 T Auger Motor C E 017 Breckwell Maintenance Tool A TOOL 96 Burnpot A S BURNPOT Circuit Board Control Panel C E 401 Combustion Blower A E 027 Convection Blower A E 033 Door Gasket C G 050...