1
DSB System (Platform with Indicator)
Quick User Guide
Connect Platform to Indicator
The DSB system includes a platform and scale indicator. Securely connect the cable from the platform to the
indicator by tightening the quick disconnect fittings together.
Power up the Indicator
1.
The indicator is powered by an A/C adapter that plugs directly into the DC pin at the bottom of the
indicator.
2.
Press
for 2 seconds to turn the indicator on or off. After a self test, the weighing mode will be
accessed.
Zero Operation
Initial zero setting
During power up if the weight on the scale is within the initial zero tolerance, indicator will show zero
automatically.
Manual zero
When the scale is stable and the weight is not negative, you can zero the weight within tolerance by briefly
pressing the
key.
Tare Operation
Perform a tare to remove the weight of a container and just weigh the contents. During tare operation, when the
gross weight is tared, the indicator display will show the Net weight. The Net annunciator will also be lit.
From the TARE mode, press the
key to clear the tare weight. The indicator display will return to the gross
weight.
Accumulation Operation
1.
With
0
on the display, add the weight to the scale. Briefly press the
key to enter the accumulation
mode. The
Total
annunciator turns on and the display shows
n 001
briefly and returns to the loaded
weight.
2.
Unload the weight. The display shows
0
.
3.
Load the second weight and press the
key.
n 002
is displayed then the display goes back to the
loaded weight.
4.
Repeat it for a maximum 999 times.