10
EN
• Pull the lock (21) of the upper lid (22) and open the
lid (22) (pic. 7)
• Remove the separator (20) (pic. 7), turn the HEPA
filter (19) clockwise and remove it (pic. 8).
• Remove dust and garbage from the separator (20)
(pic. 8).
• Wash the separator (19) under a warm water jet and
then dry it.
•
Wash the HEPA filter (19) under a warm water jet and
dry it (pic. 8).
• Do not wash the parts in a dishwashing machine.
•
Dry the HEPA filter (19) thoroughly.
•
Do not dry the HEPA filter (19) with a hairdryer or
similar appliances.
•
Wash the dust bin flask (23), wipe it and dry.
•
Install the HEPA filter (19) in the separator (20) and
turn it counterclockwise as far as it will go.
•
Insert the separator (20) into the flask (23).
• Close the lid (22) until the lock (21) catches.
• Install the assembled dust bin (11) back to its place,
make sure that the dust bin (11) is fixed properly.
•
Remove the outlet filter grid (18), turning it clockwise
and remove the outlet filter (17) (pic. 9).
•
Wash the outlet filter (17) and the grid (18) under a
lukewarm water jet. Do not wash the outlet filter (17)
and the grid (18) in a dishwashing machine.
•
Dry the outlet filter (17) and the grid (18).
•
Install the outlet filter (17) back to its place.
• Install the grid (18) back to its place, turn the grid (18)
counterclockwise as far as it will go.
Vacuum cleaner body
• Clean the vacuum cleaner body with a soft, slightly
damp cloth, and then wipe it dry. Provide that no
liquid gets inside the vacuum cleaner body.
• Do not use solvents or abrasives for cleaning the
vacuum cleaner body and the attachments.
• Do not immerse the vacuum cleaner body, the power
cord and the power plug into water or any other
liquids.
OVERHEATING PROTECTION
• If the electric motor gets too hot during the operation,
the overheating protection system will be set off.
• If during cleaning the vacuum cleaner has switched
off, press the on/off button (16) and unplug the unit.
•
Let the vacuum cleaner cool down for 30-40 minutes
and switch it on again. The cool-down time can
differ from the given value, depending on the room
temperature.
Attention!
Before assembling and installing the dust bin (11)
back to its place, make sure that the HEPA filter (19),
the separator (20) and the flask (23) are dry.
Cleaning the outlet filter (17)
•
Switch the vacuum cleaner off and unplug the power
cord plug from the mains socket.
Содержание BR4209
Страница 1: ...Instruction manual Инструкция по эксплуатации Vacuum cleaner BR4209 Пылесос BR4209 brayer ru ...
Страница 2: ...СОДЕРЖАНИЕ EN 3 DE 12 RU 22 KZ 32 ...
Страница 4: ...4 EN 1 2 3 4 5 10 6 9 7 8 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 27 26 ...
Страница 5: ...5 EN Pic 1 Pic 2 Pic 3 Pic 4 Pic 5 Pic 6 Pic 7 Pic 8 Pic 9 ...
Страница 13: ...13 DE 1 2 3 4 5 10 6 9 7 8 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 27 26 ...
Страница 14: ...14 DE Abb 1 Abb 2 Abb 3 Abb 4 Abb 5 Abb 6 Abb 7 Abb 8 Abb 9 ...
Страница 23: ...23 RU 1 2 3 4 5 10 6 9 7 8 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 27 26 ...
Страница 24: ...24 RU Рис 1 Рис 2 Рис 3 Рис 4 Рис 5 Рис 6 Рис 7 Рис 8 Рис 9 ...
Страница 33: ...33 KZ 1 2 3 4 5 10 6 9 7 8 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 27 26 ...
Страница 34: ...34 KZ Сур 1 Сур 2 Сур 3 Сур 4 Сур 5 Сур 6 Сур 7 Сур 8 Сур 9 ...
Страница 42: ......
Страница 44: ...brayer ru ...