Содержание Omnitest 3

Страница 1: ...Omnitest 3 B Braun Melsungen AG OPM Carl Braun Straße 1 34212 Melsungen Germany ...

Страница 2: ...cose results of the Omnitest 3 system without prior consulting your physician The Omnitest 3 system provides a quick and easy way to measure the blood glucose level Omnitest 3 can be used for self monitoring of blood glucose level by diabetes patients It should be used only for testing blood glucose sugar and only with fresh capillary whole blood samples It should not be used for the diagnosis of ...

Страница 3: ...17 Checking the Meter Display 19 Check Strip 20 Using Control Solution 22 Set the Meter 29 Reviewing Your Results 40 Deleting Test Results 41 Collecting a Drop of Blood Sample 42 Testing Your Blood Glucose 46 Marking Function 54 Maintain Your Blood Glucose Monitor System 56 Troubleshooting 58 Specifications 62 Transfer Test Results to a Computer 65 Blood Glucose Conversion Table 66 ...

Страница 4: ...Omnitest 3 Blood Glucose Monitoring System Omnitest 3 Omnitest 3 meter Two 3V lithium batteries CR2032 Check strip Omnitest 3 test strips may be sold separately Omnitest 3 Control solution sold separately ...

Страница 5: ...hown on the outer packaging If anything is missing please return your system to the place of purchase or contact your nearest B Braun representative H 3 5mL 3 olllösung ol solution on de contrôle plossing one di controllo test 3 Control H 1 M 3 5mL lllösung l solution on de contrôle plossing one di controllo test 3 Control M Lancets and lancing device are only parts of the Omnitest 3 Set ...

Страница 6: ...CD display Up button Power Select button Down button Backside Product label Battery cover Strap holder Data transfer port Omnitest 3 www omnitest bbraun com Omnitest 3 B3MLG 2010 01 Omnitest 3 mmol L B Braun Melsungen AG OPM Germany www bbraun com GKGBGBS00266 ...

Страница 7: ... 24 o clock 0 12 o clock 7 Display Segments The battery symbol means the battery is low and has to be changed The DEL mark will display when you can delete results from the meter memory The MEM mark will display while reviewing the results The SET mark will display during ALL meter setting Control solution symbol Before Having a Meal After Having a Meal After Taking Medication Segment Meaning Segm...

Страница 8: ...BGBS00266 B3MLG 2010 01 Omnitest 3 mmol L B Braun Melsungen AG OPM Germany www bbraun com GKGBGBS00266 3 fen trips mie ps test Code Control M Mean Control H Mean B Braun Melsungen AG O 34209 Melsungen Germa 06 2019 C21 8 2 Omnitest 3 Omnitest 3 8 Quick Reference Insert batteries Insert test strip Close test strip vial ...

Страница 9: ...mnitest 3 Omnit CODE 3 fen trips mie ps test Code Control M Mean Control H Mean B Braun Melsungen AG O 34209 Melsungen Germa 06 2019 C21 8 2 2019 C21 9 Code is automatically recognized and displayed Ready for measurement ...

Страница 10: ... 10 Quick Reference Get blood sample with lancing device ...

Страница 11: ... Wait 3 sec for result Eject test strip Omnitest 3 Omnit Omnitest 3 Omnit Omnitest 3 Omnit Omnitest 3 Omnitest 3 11 Apply blood sample Omnitest 3 Omnit ...

Страница 12: ...ed with Omnitest 3 test strips for accurate analysis of your blood glucose level Use the test strip exactly as described in the user s manual for Omnitest 3 test strips Opening of the measurement chamber Confirmation window Meter contacting leads Auto coding label Omnitest 3 ...

Страница 13: ...itest 3 test strip This keeps the strips fully functional right up to the expiry date Use test strip immediately after removing it from the vial Do not use test strips after the expiration date printed on the package or vial since it may cause inaccurate results Make a notation on the vial label of the date when you first open it Discard remaining Omnitest 3 test strips 6 months after first openin...

Страница 14: ...C 104 F and above 90 relati ve humidity Warning Keep the test strip bottle away from children A child could choke on the cap or the test strips The test strip and the vial wall contain agents that may be harmful if swallowed NOTE Please refer to the user s manual for Omnitest 3 blood glucose test strip for additional information Omnitest 3 Blood Glucose Test Strip ...

Страница 15: ...ibrates the Omnitest 3 meter automatically Before testing make sure that the code number of the test strip vial matches the code shown on the meter If these two code numbers match you can start testing Omnitest 3 Omnit 3 fen trips mie ps test Code Control M Mean Control H Mean B Braun Melsungen AG O 34209 Melsungen Germa 06 2019 C21 8 2 CODE 2019 C21 ...

Страница 16: ...ose level Make sure that you are checking the code against the right vial Verify that the auto code label on the back side of the test strip is undamaged Insert the test strip again or try another test strip If problem still exists please contact your local distributor for warranty services CAUTION Do not test if the code numbers do not match ...

Страница 17: ...ay or when the meter does not power on by any means The meter needs two 3V lithium batteries CR2032 Batteries are provided with the Omnitest 3 meter system The Omnitest 3 system could also operate with a single 3V lithium battery CR2032 which will reduce the operating time ...

Страница 18: ...rst all segments of the display will be shown Thereafter an internal check of the electronic takes place in the following seconds Correct the date and time setting after the battery change B3MLG 2010 01 Omnitest 3 mmol L B Braun Melsungen AG OPM Germany www bbraun com GKGBGBS00266 www omnitest bbraun com Omnitest 3 B3MLG 2010 01 Omnitest 3 mmol L B Braun Melsungen AG OPM Germany www bbraun com GKG...

Страница 19: ...splay will appear for 3 seconds The numbers displayed are only meant for internal tests of the electronics Also after inserting a test strip all segments will be displayed The following picture shows all possible display segments so that you could check that the display is working properly ...

Страница 20: ... 20 Check Strip Meter is ok Omnitest 3 Omnitest 3 The check strip is used to test that the Omnitest 3 meter is working properly Insert check strip into meter Meter will be automatically turned on ...

Страница 21: ...se monito ring Please contact your local distributor for warranty services It is recommended to do this test before first use and always if you suspect the meter is not properly working NOTE Any time the meter is powered on via test strip insertion the electronic per forms a self test In case of any prob lems an error code will be displayed ...

Страница 22: ... properly If your blood glucose test results are not consistent with your symptoms or if you think they are not accurate If you have dropped the meter For quality control in the point of care usage For teaching or learning the system To perform a control solution test follow the same test pro cedure as for a blood glucose test substituting control solution for the drop of blood For detail instruct...

Страница 23: ...on is cold do not use until the solution has warmed up to room temperature Control solution tests have to be done in a temperature range 20 25 C 68 77 F Insert a test strip Push the test strip until it will go no further without bending the strip The meter will automatically turn on ...

Страница 24: ...tion vial gently Remove the cap Squeeze the vial discard the first drop and wipe off the dispenser tip with a clean tissue to ensure an accurate result Squeeze the vial again to get a drop Apply a drop of control solution on a clean and none absorbing base Guide the tip of the test strip toward the drop until it is drawn up by the test strip O m n i t e s t 3 O m n i t e s t ...

Страница 25: ... 25 Once you hear the beep it means the test strip is completely filled The meter begins to count down 3 to 1 and then the result is displayed ...

Страница 26: ...ed with the range printed on the test strip vial The result should fall within the range Omnitest 3 Omnit 3 fen trips mie ps test Code Control M Mean Control H Mean B Braun Melsungen AG O 34209 Melsungen Germa 06 2019 C21 8 2 mmol L 4 5 6 3 5 4 12 6 17 4 ...

Страница 27: ... or contaminated control solution Control solution that is too warm or too cold Failure to discard the first drop of control solution and wipe the dispenser tip clean Contamination of the control solution e g if the drop of the control solution is taken back into the control vial Meter malfunction Test strip deterioration Do not use the Omnitest 3 system to test your blood glucose until you get a ...

Страница 28: ... tests with sym bol to distinguish from blood glucose tests in the meter memory Marked control solu tion test results will not be included in your averages Marking Function Press or button after the measurement to choose the control solution symbol among the available symbols ...

Страница 29: ...ntend to change any of the settings you need to enter the setting mode Turn on the meter by pressing button and hold for 3 seconds This will initiate the Set the Meter mode SET icon will appear on the display during the setting ...

Страница 30: ... C or F average day The Omnitest 3 meter has 6 functional setting modes To go to the next step of the setting mode press the button To leave the Set the Meter mode at any time press the button for 3 seconds If you have missed out a setting start the Set the Meter procedure again ...

Страница 31: ... 31 Set the 12 Hour or 24 Hour Mode If you are in the Set the Meter mode at first you can change the hour mode Press or button to select the proper time system ...

Страница 32: ... range from 2009 to 2099 which is not displayed in normal operation NOTE Without setting the date properly the average glucose level and the results in memory will not show proper value It is highly recommended to set the meter before use and to check the time when a new battery is installed You can not test your blood glucose while in the setting mode ...

Страница 33: ...n and the month setting will start flashing Press or button to select the month and then press button to set the day After that press button to set time Press or button to select the appropriate hour press button to set minutes YR Year MON Month DAY Day ...

Страница 34: ...m setting Alarm setting order is AL1 AL2 AL3 AL4 AL5 If the AL2 is OFF the rest of AL3 AL5 are all OFF Press or button to select the ON OFF of alarm function If you choose ON press button to set the time for alarm Press or button to set the proper alarm time hour press button to set minutes Press button to set next alarm ...

Страница 35: ...m The alarm will not work during the testing of blood glucose The loudness of the alarm is intended to remind you of a glucose measurement but not to wake you up from deep sleep The alarm buzzer is always turned on even when the buzzer is set to OFF ...

Страница 36: ...o set the buzzer Buzzer character bEEP will appear on the display Press or to select ON OFF the buzzer sound NOTE There is no beep sound during buzzer is OFF when test strip inserted sufficient blood sample applied and when test result is displayed ...

Страница 37: ... 37 Set the Temperature Unit Press button to set the temperature unit Press or button to select the proper temperature unit ...

Страница 38: ... 3 will show 3 different average results and the number of days can range from 1 to 99 days The setting mode begins with setting the number of days of which you would like to receive an average calculation of your glucose level E g 7d 7 days average First average setting Second average setting ...

Страница 39: ... button or button holding the or button the value will be increased or decreased at a quicker rate With the correct number of days displayed press button to set next average day AVG character will display during the average day setting Third average setting ...

Страница 40: ...play by recalling anytime you like to see them The latest result will replace the oldest beyond 365 data The meter enters Memory mode by pressing the button shortly The first display shows the latest test result Press button to see the individual test results Press button to see the average results Small AVG icon will be shown on the display 7d 7 days average 23n 23 results taken for average calcu...

Страница 41: ...ng sounds will be heard and the test result disappears from the display To delete all test results press buttons at the same time for 3 seconds and then big dEL character will be displayed Keep on pres sing buttons until 3 beeping sounds will be heard and dEL disappears from the display Average results AVG can not be deleted because they are calculated from the remaining test results in the memory...

Страница 42: ...f the carrier Twist off the protective cover of the lancet Replace the threaded tip of the Omnilance device The comfort tip offers 5 different levels of skin penetration To select best depth 1 2 for soft or thin skin 3 for average skin 4 5 for thick or calloused skin To select a desired depth move the number to match the arrow ...

Страница 43: ...ding barrel with the other hand As the ends are pulled apart the spring tension increases When a click is felt the spring tension is locked and the device is ready for use Release the sliding barrel It will automatically move back to its original position ...

Страница 44: ...ip Set aside Omnilance and wait a few seconds for a blood drop to form The flow of blood will be helped by keeping the hand warm by lowering the hand to waist level and by gentle mas sage of the finger Never allow another person to use a lancet that has already been used The lancing device has only to be used by one person and has not to be lend since the tip could be contaminated ...

Страница 45: ...barrel to dispose the lancet For safety reasons and to prevent cross contamination discard the used lancet into an appropriate sharps or biohazard container Taking Care of Your Omnilance Use mild soap and water to wipe the outside of the lancing device For more complete cleaning remove the tip wash the tip in warm water and rinse well ...

Страница 46: ... Alcohol dirt or perspiration may affect the test result Lancing Prepare the lancing device and lancet Insert an unused needle lancet in the lancing device Refer to page 42 for more information NOTE Read the additional information given in the instruc tions for use of the test strips Your healthcare profes sional will advice you on your ideal blood glucose range Consult your physician before makin...

Страница 47: ...ing the other strips Insert a test strip Push the test strip until it will go no further without bending the strip The meter will automatically turn on First all display segments and then the code number is shown Omnitest 3 Omnitest 3 3 fen trips mie ps test Code Control M Mean Control H Mean B Braun Melsungen AG O 34209 Melsungen Germa 06 2019 C21 8 2 ...

Страница 48: ...s the test strip code and adjusts the meter accordingly Make sure the code number on the display matches the code number on the test strip vial Omnitest 3 Omnit 3 fen trips mie ps test Code Control M Mean Control H Mean B Braun Melsungen AG O 34209 Melsungen Germa 06 2019 C21 8 2 CODE 2019 C21 ...

Страница 49: ...sing a new test strip see also page 15 Automatic Coding of the Meter If any different message appears on the display due to several causes and conditions please refer to Troubleshooting page 58 Do not perform blood glucose tests at a temperature below 10 C 50 F or above 40 C 104 F and above 90 relative humidity ...

Страница 50: ...ood Glucose Ready for the Measurement 2 seconds after code display blood icon will be displayed on the screen Date and time information are shown at the bottom Omnitest 3 is now ready for the measurement Omnitest 3 Omnit ...

Страница 51: ... 51 Applying Blood Sample Prick the area where you have decided to obtain the blood Touch your finger to the tip of Omnitest 3 test strip to apply the blood sample Omnitest 3 Omnit ...

Страница 52: ...imal sample volume is 0 3 µL Do not allow blood to flow aside the test strip into the meter This could lead to malfunction NOTE Do not force your finger against the test strip Do not try to apply a smeared sample Do not add blood to the test strip after the beep sound Do not squeeze the fingertip The meter will power off automati cally after 3 minutes if no testing was done on the test strip In th...

Страница 53: ...the numbers from 3 to 1 on the display Then the test result will be shown in mmol L millimoles of glucose per litre of blood Date and time information are displayed under the test result The Omnitest 3 meter displays results between 0 6 33 3 mmol L Omnitest 3 Omnit Omnitest 3 Omnit ...

Страница 54: ...r Customer Service You cannot change the unit of measure Using the wrong unit of measure may cause you to misinterpret your blood glucose level and could lead to incorrect treatment Marking Function If required you can press the or button to choose one of the following marks Before having a meal After having a meal After taking medication Control solution or no marker The result is stored automati...

Страница 55: ...ward to remove the test strip from the meter while it is directed downwards The meter is turned off with the removal of the test strip Discard the used test strip and the lancet according to the local regulations Omnitest 3 Omnitest 3 Omnitest 3 Omnit Omnitest 3 Omnit ...

Страница 56: ... the meter but chemical solution such as benzene or acetone MUST NOT be used since either of those can harm and damage the meter surface When cleansing the meter with pure alcohol DO NOT pour directly onto the meter but use the cloth soaked with a small amount of alcohol After cleansing the meter dry completely at a cool place avoiding direct sun light The meter or the test strips are not to be pl...

Страница 57: ...rts of Omnitest 3 in the pouch together and keep it at a cool and dry place out of the reach of children Do not refrigerate Avoid exposure to the sun For detailed storage instructions for Omnitest 3 test strips refer to the user s manual of Omnitest 3 test strips The lancing device should be cleaned if blood or stain remains after test for infectious disease prevention Discharge used materials acc...

Страница 58: ...used by a used or wet test strip Repeat the test with a new test strip Apply a sufficient amount of blood There is a problem with the test strip Test strip is damaged Repeat the test with a new test strip Error message that indi cates that the blood or control solution sample was applied before the symbol appeared on the display Repeat the test with new test strip Apply blood or control solution o...

Страница 59: ...e is a problem with the auto code detection If the LCD screen shows Sun message alternately with Er 6 avoid the direct sunlight and insert test strip again No results obtained on the meter The meter memory is empty until you perform a first blood glucose measurement The ambient temperature is too low Place the meter at the oper ating temperature range 10 40 C 50 104 F for more than 10 minutes and ...

Страница 60: ...blood sam ple two or three times When HI message persists please consult a doctor for assistance In case of doubt of blood test result check the meter with control solution With normal result re test with blood sam ple two or three times When Lo message persists please consult a doctor for assistance Place the meter at the oper ating temperature range 10 40 C 50 104 F for more than 10 minutes and ...

Страница 61: ...st strip or meter Apply sufficient amount of a fresh sample to a new blood glucose test strip and re test Conduct a control solution test or a check strip test The code numbers of the meter and of the test strip vial do not match Different result in comparison with another meter The meter does not power on Test does not start after applying sample Re test with a new test strip If the problem persi...

Страница 62: ...ults with date and time Operating Temperature 10 C 40 C 50 F 104 F Operating Humidity 10 90 Sample Type Fresh capillary whole blood Sample Volume 0 3 µL Display Type LCD Size L x W x H 83 x 56 x 18 mm Weight including battery 54 g Power Supply 2 x 3V lithium batteries CR2032 Battery Life 3000 tests ...

Страница 63: ...stic medical devices In vitro diagnostic medical device Batch code Catalogue number Temperature limitation Do not re use Use within 3 or 6 months after first opening Caution consult accompanying documents Direct current Omnican Lance soft Do not use if the protective cap is missing or damaged Symbol Description 63 6 3 ...

Страница 64: ... years after first use of the device Test Principle The enzyme glucose oxidase on the test strip reacts specifically with the blood glucose The current generated is converted and displayed as blood glucose value The Omnitest 3 system is plasma calibrated to allow easy comparison of results with laboratory methods Blood glucose meters which are calibrated against a whole blood method may have diffe...

Страница 65: ... can be further analyzed To make use of this feature you need the Omnitest 3 PC interface cable REF 9152856G as well as a link to the Online Diary Omnitest Center The monitor will display PC as soon as the cable is connected to the PC and the software is activated For further information see www omnitestcenter com Omnitest 3 ...

Страница 66: ...ion Table mmol L to mg dL mmol L mg dL 2 8 50 1 0 18 1 5 27 2 0 36 2 2 40 2 5 45 3 0 54 0 55 10 8 3 150 mmol L mg dL 7 0 126 7 2 130 7 5 135 7 8 140 8 0 145 8 9 160 6 7 120 mmol L mg dL 14 4 260 15 0 270 16 0 288 16 6 300 17 0 306 18 0 325 19 0 342 20 0 360 ...

Страница 67: ... 70 4 0 72 4 4 80 4 7 85 5 0 90 5 5 100 6 0 108 6 1 110 9 0 162 9 4 170 10 0 180 10 5 190 11 0 196 11 1 200 12 0 216 12 5 225 13 9 250 20 8 375 22 2 400 23 0 414 24 0 432 25 0 450 26 4 475 27 7 500 30 0 540 33 3 600 ...

Страница 68: ...esentative or go to www omnitest bbraun com 2013 05 B3MMMGB 9334990MMGB B Braun Melsungen AG OPM Carl Braun Straße 1 34212 Melsungen Germany Tel 49 0 5661 71 3399 Fax 49 0 5661 71 3550 www bbraun com www diabetes bbraun com Distributed by B Braun Australia Pty Ltd 17 Lexington Drive Bella Vista NSW 2153 AU ...