background image

2

1

English

Forehead  

thermometer

FHT 1000

English 

 4

Español 13

Contact Us

  

Questions or Comments?  

    1-800-327-7226   

eMail: 

 [email protected] 

Visit:

  www.kaz.com/braun 

Write: 

Consumer Relations, Kaz USA, Inc.,  

250 Turnpike Road, Southborough, MA 01772, USA 

Kaz USA, Inc., 250 Turnpike Rd., Southborough, MA 01772, USA
This product is distributed by Kaz USA, Inc, under license to the ‘Braun’ trademark.   
‘Braun’ is a registered trademark of Braun GmbH, Kronberg, Germany.

Contáctenos

  ¿Preguntas o Comentarios? 

 

  1-800-327-7226 

Correo electrónico

: [email protected] 

 

Visite:

   www.kaz.com/braun

E

scriba a:

 Consumer Relations, Kaz USA, Inc.,  

250 Turnpike Road, Southborough, MA 01772, EEUU 

Kaz, USA, Inc., 250 Turnpike Rd., Southborough, MA 01772, EEUU
Este producto es distribuido por Kaz, USA, Inc, bajo licencia de la marca registrada ‘Braun’.  
‘Braun’ es una marca registrada de Braun GmbH, Kronberg, Alemania.

31IM1000291
USA/MEX 
Patents/Patentes: www.kaz.com/patents/braun

Made in China/Hecho en China

18APR13
© 2013 Kaz USA, Inc.

Содержание FHT 1000

Страница 1: ...is a registered trademark of Braun GmbH Kronberg Germany Cont ctenos Preguntas o Comentarios 1 800 327 7226 Correo electr nico consumerrelations kaz com Visite www kaz com braun Escriba a Consumer Re...

Страница 2: ...ions when using on children Never immerse the Forehead thermometer into water or other liquids not waterproof For cleaning and disinfecting please follow the instructions in the Care and cleaning sect...

Страница 3: ...hy use the Braun Forehead thermometer Measurement in under 3 seconds The innovative infrared technology allows measurement of forehead temperature in under 3 seconds Accurate and reliable Due to advan...

Страница 4: ...wer button once Backlight will come on and the warm up sequence starts Ready When device displays STEADY 00 on the screen it s ready to take a measurement 3 Position Position the thermometer on the fo...

Страница 5: ...use Calibration The thermometer is initially calibrated at the time of manufacture If this thermometer is used according to the use instructions periodic re adjustment is not required If at any time...

Страница 6: ...ith positive and negative as shown Replace the battery door and close securely Replace the batteries when the flashing battery symbol appears on the LCD screen Dispose of batteries according to local...

Страница 7: ...yrequirementsforthethermometeronlyinthedisplayrangeof96 8 Fto 102 2 F 36 Cto39 C forinfraredthermometersis 0 4 F 0 2 C whereasformercury in glass andelectronicthermometers therequirementperASTMStandar...

Страница 8: ...r favor consulte a su m dico si observa s ntomas tales como irritabilidad inexplicable v mitos diarrea deshidrataci n cambios en el apetito o en la actividad convulsiones dolor muscular temblores rigi...

Страница 9: ...orcionar n la mayor precisi n El term metro de Frente ha sido cl nicamente probado y demostrado para ser seguros y preciso cuando se usa de acuerdo con su manual de operaci n La temperatura normal es...

Страница 10: ...os de toma de temperatura Los pacientes deben permanecer en una condici n constante en la habitaci n durante al menos 30 minutos Sostenga el term metro al ras de la frente y pase lentamente encima de...

Страница 11: ...ca de memoria para recuperar la ltima lectura de temperatura La ltima temperatura tomada se almacena en su memoria y se mostrar autom ticamente durante 2 segundos cuando se vuelva a encender Errores y...

Страница 12: ...o de no rayar la superficie de la pantalla colocando la tapa protectora despu s de cada uso Especificaciones del Producto Tipo Term metro de Frente FHT1000 Rango de medici n 93 2 F 108 F 34 C 42 2 C R...

Отзывы: