Страница 2: ...t proper flow or water circulation as this may cause damage to the unit CAUTION This unit is not intended for use with temporary or fold able storable pools All pipe work associated with this system i...

Страница 3: ...17 ENG rev 2 0 P a g e 3 15 Contents Control Unit Features 4 Installation Guide 5 Important Notes 6 Installation Layout Drawings 7 Operating instructions 11 Maintenance 12 Water Chemistry balancing In...

Страница 4: ...e run indicator 7 Pump Outlet Socket 2 Chlorine Cell output display 8 Air Filter 3 Fuse 9 Ozone Output 4 Sanitation Switch 10 Positive Cell Lead red 5 Master Switch 11 Negative Cell Lead black 6 Chlor...

Страница 5: ...umb chlorine cell onto return pipe after filter ensuring there is a gas trap see images below Step 3 Plumb Ozone injector manifold after chlorine cell on the return line of the pool ensuring direction...

Страница 6: ...sion values In situations where a heater is incorporated the Ozone Swim cell housing must be installed after the heater Should a solar heating system be installed the housing must be plumbed after the...

Страница 7: ...Ozone Swim 1000 2000 and 3000 series User Manual JULY 2017 ENG rev 2 0 P a g e 7 15 Ozone Swim 1000 2000 3000 Installation Layout Drawings Standard Non Flooded install...

Страница 8: ...Ozone Swim 1000 2000 and 3000 series User Manual JULY 2017 ENG rev 2 0 P a g e 8 15 Flooded Installation For installations where control box is below water level...

Страница 9: ...Ozone Swim 1000 2000 and 3000 series User Manual JULY 2017 ENG rev 2 0 P a g e 9 15 Installation with De Gas Chamber...

Страница 10: ...neral cell is switched off until the salt minerals have been completely dissolved in the pool To achieve the correct salt mineral levels in new pools you need to know the pool capacity you can then wo...

Страница 11: ...ff peak tariff we recommend the use of an appropriate battery backup time clock for that purpose Checking Chlorination output The chlorine cell output controller regulates the amount of chlorine produ...

Страница 12: ...f 1 15 25 or 28 indicates the Amperage current being applied to the cell OF Cell output control knob is turned off the Ozone Swim s chlorination has been manually switched off dg Automatic cleaning cy...

Страница 13: ...ur pool s application and location Water Chemistry balancing Information Regular water testing must be performed to ensure the water Is within the recommended ranges see below Chlorine 1 3 ppm Hardnes...

Страница 14: ...d remove and replace water as required No display No mains power Ozone Swim plug removed from power point Ozone Swim fuse blown Unit is turned off Ensure there is mains power available Ensure Ozone Sw...

Страница 15: ...ducts are designed and tested to conform to AS NZS 3136 AS NZS 3100 To comply with this standard the chlorinator must not be installed in the pool zone Trademarks Throughout this document trademark na...