8
• Ergonomic design and compact body.
• “6 position type head” allows direction of contra angle head to be changed and the ON/OFF
key to be set to a position where it can be easily activated.
• The larger ON/OFF key enhances operability (compared with conventional products).
• Operates continuously for approx. 1.2 hour at rated load. (Dependent upon use conditions.)
• The liquid crystal panel enhances ease of use.
• Memory for up to 5 programs .
• The auto reverse function is activated depending on the load. A wide variety of functions
such as “AUTO REVERSE”, “AUTO STOP” and “AUTO REVERSE OFF” are available. The
memory can store these functions combined with nine different operation programs.
1. Features
Symbols
TUV Rhineland of North America is a Nationally Recognized Testing Laboratory (NRTL)
in the United States and is accredited by the Standards Council of Canada to certify
electro-medical products with Canadian National Standards.
Class II equipment
• This product does not consider patient’s age (except infants), gender, weight or nationality.
• The motor handpiece is designed for commercially available AAA nickel metal hydride
batteries (rechargeable). Ni-Cad batteries can also be used, but the charging time and
operating time become significantly shorter since the charging current differs.
• The motor handpiece consumes electricity very slightly even when the power is off. In
addition, fully-charged rechargeable batteries, in general, discharge gradually over time
even though it is not used. It is recommended to recharge the batteries just before use.
• When the motor handpiece automatically stops by detecting a low battery voltage, leaving
it for a while and turning on the power again may not detect the low voltage immediately.
This is not a failure, but due to battery characteristics. The voltage drop does not coincide
with the remaining battery capacity.
• Recharge rechargeable batteries after they deplete as much as possible. Repeating short
time use and subsequent recharging may shorten their operating time due to a “memory
effect.” Batteries may recover from the memory effect after fully discharging and then fully
charging and repeating this procedure a few times.
• Eventually completely discharged batteries cannot be charged and need to be replaced.
• User shall be responsible for operation, maintenance and operation.
• No special training is required for this device.
NOTICE
Refer to the Operation Manual.
Type B conforming component
A manufacturer's name and address
Follow the waste of electric and electronic equipment (WEEE) Directive (2002/96/CE)
to dispose of the product and accessories.