background image

PLUS ADVANTAGE

®

COATED STAINLESS STEEL GAS CONNECTORS 
INSTALLATION INSTRUCTIONS

DO NOT INSTALL THIS PRODUCT UNTIL YOU HAVE READ AND UNDERSTAND  

ALL INSTRUCTIONS!

The PLUS ADVANTAGE™ coated stainless steel gas connector combines two 

state-of-the-art technologies to deliver a superior gas connector for your home and 

family.  PLUS ADVANTAGE gas connectors feature an advanced corrosion 

resistant coating called ProCoat®. A proprietary polymer coating, ProCoat is specially 

engineered to resist the corrosion from harsh chemicals found in household cleaning, 

plumbing repair and masonry products. Approved for indoor and outdoor use, ProCoat  

is formulated to resist the harsh effect of UV rays and salt.
PLUS® excess flow valves (EFV), an automatic safety valve for gas, utilize a 

patented magnet-based excess flow technology.  In the event of a gas line rupture or 

disconnection at the appliance, the PLUS valve immediately restricts gas flow to 

a non-hazardous level (a bypass flow) to avert the potential for a dangerous release of 

gas into the home.  Only after the gas line has been properly repaired, the bypass flow 

automatically resets the valve, allowing gas flow to resume to the appliance.
•   Use only on low pressure natural and LP gas piping systems.  DO NOT USE on 

  pipelines or piping systems that transfer or move liquids, including high-pressure   

  liquid propane.
•   Use only with gas line pressures at a minimum of 4” water column (W.C.) and not   

  greater than 14” W.C. (1/2 psig) at the stub out.  
•   Use only in connection with residential and commercial gas appliances, where    

  installation is immediately downstream of the gas supply stub out and manual gas  

  shut-off valve.

Tools Needed for Installation:

 

    

  • (2) 10" adjustable wrenches  

  • Pipe dope or gas pipe thread tape  

  • Leak detection solution

SIZING THE CONNECTOR TO THE APPLIANCE

1.  Measure the distance between the gas supply stub out and the appliance.  

  Add 2 – 3 inches to the measured distance for appropriate connector length for the  

  installation. (See Fig. A)

2.  Identify the maximum (gas) input rating of the  

  appliance (refered to as “input rating”).  

  Manufacturer’s label, located near the gas inlet  

  of the appliance will  contain this information.  

  (See Fig. B) Contact the appliance manufacturer  

  if you are unsure of the correct rating for the  

  appliance.
3.  Using Chart 1, select the gas connector with the  

  maximum flow capacity that is HIGHER than the  

  input rating of the appliance. However, select the  

  gas connector with the maximum flow capacity  

  that is CLOSEST TO the input rating of the  

  appliance. (Figure C)

 

WARNING:

 The maximum gas input rating of the 

  appliance must be within the flow capacity range  

  of the connector.  If the PLUS gas  

  connector is not properly sized to the application,  

  the PLUS connector may not activate in  

  the event of a gas line rupture or disconnection.  

  If the PLUS gas connector is under sized  

  for the appliance, may activate prematurely  

  restricting gas flow during normal operation of  

  the appliance.   
4.  Finally, select the connector with the end fittings  

  that match the outlet of your manual gas shut-off  

  valve and the gas inlet to the appliance. (Figure D)

 

NOTE

: All PLUS valves require minimum inlet pressure of 4” W.C. and are   

  rated at a maximum inlet pressure of 1/2 psig. (14” W.C.). Flow rates given    

  are for 0.6 specific gravity natural gas with an average heating value of 1000   

  BTU per cubic foot; therefore, 1,000 BTU/Hr is equal to 1 SCFH (standard cubic  

  foot per hour).Chart to be used in accordance with the local plumbing codes and  

  with reference to IAPMO/ANSI UPC 1-2003; NFPA 54/ANSI Z223.1 - National    

  Fuel Gas Code.

INSTALLATION INSTRUCTIONS

SAFETY PRECAUTIONS:

1.  Read and follow all installation instructions carefully. 

  When in doubt, call a licensed plumber or your local  

  gas company.
2.  DO NOT reuse the gas connector or fittings.   

  The connector, fittings and valve are designed for  

  use on original installation only.  Removal of  

  connector and additional handling may have  

  damaged connector making it unsafe for reuse.
3.  DO NOT use this gas connector on appliances  

  equipped with rollers or casters. (Figure E)  

  This connector is designed for limited movement  

  after installation.  Repeated bending, flexing or  

  extreme vibration can cause metal fatigue. DO NOT  

  repeatedly move appliance for cleaning  

 

  once installed. 
4.  AVOID connector contact with foreign objects such as wall studs, electrical wiring,   

  copper or iron pipe, paneling sheet metal, etc. Gas systems should NOT be used as  

  electrical grounds. Dissimilar metals should be isolated from each other.
5.  Keep cleaning solvents containing ammonia or chlorine away from uncoated gas    

  connectors. (Figure F) DO NOT store these solutions in closets containing a water    

  heater or furnace. Chlorine can corrode uncoated stainless steel. 

Fig. A

For Residential 
and Commercial 
Gas Appliances

CONNECTOR

CAPACITY

36”

33,400

63,000

125,000

63,000

GAS APPLIANCE

INPUT RATING

62,500

Fig. B

CONNECTOR 

CAPACITY 

 

36” 

33,400 

63,000 

125,000 

71,100

GAS APPLIANCE 

INPUT RATING 

62,500 

Fig. C

CONNECTOR

CAPACITY

36”

33,400

63,000

125,000

63,000

GAS APPLIANCE

INPUT RATING

62,500

Fig. D

Gas Connector Maximum Flow Capacity

Part #

EFV Closing 

Flow Rate

ID

Color 
Code

12”

18”

24”

30”

36”

48”

60”

72”

CSSL 95,000 Btu/Hr 1/4

Purple

48,000  43,800  40,000  36,400  33,400  28,300  24,900  23,100 

CSSD 95,000 Btu/Hr 3/8

Green

75,000  70,000  70,000  63,000  65,000 60,500  53,200  49,100 

CSSC 195,000 Btu/Hr 1/2

Gold

135,000  130,000  130,000  125,000  125,000  106,000  93,200  86,000 

Chart 1

Fig. E

Fig. F