THE SAFE, EASY WAY TO INSTALL HOME GAS APPLIANCES.
Coated stainless steel gas appliance connectors provide a
safe and easy method to install gas ranges, water heaters,
ovens, furnaces and gas dryers. The corrugated tube
allows the flexibility you need to align the appliance to the
rigid gas supply pipe. The proprietary coating provides
excellent available corrosion protection from most harsh
household cleaning and plumbing repair chemicals.
❏
Approved for use with natural, manufactured, L.P.
(propane), and L.P. air mixture gases with internal
line pressure no greater than 1/2 lb. per square
inch (psi).
❏
Design certified by CSA, and listed by the New York
City Board of Standards and Appeals and the
Commonwealth of Massachusetts.
❏
Designed, Machines and Assembled in the USA and
100% leak tested.
CAUTION: DO NOT INSTALL THIS PRODUCT UNTIL YOU READ AND UNDERSTAND
ALL INSTRUCTIONS. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN
PERSONAL INJURY, PROPERTY DAMAGE OR PRODUCT FAILURE.
Even an outstanding system can become a hazard due to poor installation, inspection
or testing. Plea se read all precautions and installation instructions before beginning
connector installation.
SAFETY PRECAUTIONS:
❏
WARNING:
Gases can be ignited by a flame or spark, which may result in an
explosion.
Please follow installation instructions carefully. When in doubt, call a
licensed plumber or your local gas company.
❏
WARNING:
DO NOT re-use connectors, fittings and valves;
they are designed for
use on original installation only. Removal of connector and additional handling may
damage connector making it unsafe for reuse.
❏
WARNING:
DO NOT use this connector if it has been in a fire.
Fire can damage
the connector making it unsafe for use.
❏
WARNING:
DO NOT use this connector on
appliances equipped with rollers or casters.
This connector is designed for limited movement
after installation. Repeated bending, flexing or
extreme vibration can cause metal fatigue. Normal
vibration and movement of standard household gas
dryer or similar appliance is okay.
❏
WARNING:
DO NOT use connectors to make a
direct connection to LP gas containers.
Connection
MUST be made to the regulator device only.
❏
WARNING:
DO NOT use connector on appliances
in moving vehicles
such as RV’s, trailers, etc.
However, this product may be used in manufactured
housing (permanent residence mobile homes).
ProCoat
®
COATED STAINLESS STEEL GAS CONNECTORS
SELECTION & INSTALLATION INSTRUCTIONS
For Residential and Commercial Gas Appliances
❏
WARNING:
DO NOT use this connector with
infrared radiant tube heaters.
Cyclic movement of
heater may cause connector to fail.
❏
WARNING:
Keep cleaning solvents containing
ammonia or chlorine away from an uncoated
or damaged gas connector.
DO NOT store these
solutions near connector or use the connector near a
swimming pool or hot tub. Water rinse the connector
thoroughly if exposed to these chemical products.
❏
WARNING:
DO NOT join this connector to another connector.
❏
WARNING:
DO NOT stretch connector to make it fit
. Connector must be at least
2 to 3 inches longer than the distance from the gas supply line to appliance when
pulled out from the supply at its maximum length.
WARNING:
Connector is for use in accessible locations only.
DO NOT conceal
connector or run connector through enclosed outdoor BBQ pits, walls, partitions,
floors or appliance panels.
❏
WARNING:
DO NOT connect gas connector nuts directly to pipe threads
of gas
supply pipe or appliance. Install connector using the fittings provided. (see Figure A)
CODES AND REGULATIONS
Gas appliance and connector installation MUST conform with all local codes and
regulations including municipal and state building codes, and to all local utility
regulations. In the absence of local code, the installation must conform with the
National Fuel Gas Code ANSI Z223.1/ NFPA No. 54, Uniform Plumbing Code, or
International Fuel Gas Code. Contact your local gas company for details.
INSTALLATION INSTRUCTIONS:
WARNING:
Turn off gas supply before disconnecting old appliance. In absence of
manual shut-off valve near appliance location, gas MUST be shut off at main valve,
near meter.
NOTE:
Fuel gas codes require installation of a manual shut-off valve in the same
room, within easy reach of the appliance (i.e. within 6 feet).
1. Clean all pipe threads with a wire brush and rag to ensure connections are free
of any debris such as metal shavings, rust, dirt, oil or water.
2. Apply pipe thread sealant to the male pipe threads
of connection. DO NOT apply sealant or tape to flare
ends of fittings or shut-off valve. Sealant and tape
will prevent this connection from sealing properly.
3. If necessary, thread new manual shut-off valve onto
gas supply pipe, wrench tighten.
4. Thread steel fitting to manual shut-off valve and
other steel fitting onto appliance regulator.
5. Thread flare nuts of gas connector onto shut-off valve and steel fitting. Wrench
tighten all connections.
TO METER
Figure A
TO APPLIANCE