background image

THE SAFE, EASY WAY TO INSTALL HOME GAS APPLIANCES.

Coated stainless steel gas appliance connectors provide a 

safe and easy method to install gas ranges, water heaters, 

ovens, furnaces and gas dryers. The corrugated tube  

allows the flexibility you need to align the appliance to the 

rigid gas supply pipe. The proprietary coating provides 

excellent available corrosion protection from most harsh 

household cleaning and plumbing repair chemicals.

  Approved for use with natural, manufactured, L.P.  

  (propane), and L.P. air mixture gases with internal  

  line pressure no greater than 1/2 lb. per square  

  inch (psi).

  Design certified by CSA, and listed by the New York 

  City Board of Standards and Appeals and the  

  Commonwealth of Massachusetts.

  Designed, Machines and Assembled in the USA and 

  100% leak tested.

 

 CAUTION: DO NOT INSTALL THIS PRODUCT UNTIL YOU READ AND UNDERSTAND 

ALL INSTRUCTIONS. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN 

PERSONAL INJURY, PROPERTY DAMAGE OR PRODUCT FAILURE.

Even an outstanding system can become a hazard due to poor installation, inspection 

or testing. Plea  se read all precautions and installation instructions before beginning 

connector installation.

SAFETY PRECAUTIONS:

❏  

WARNING: 

Gases can be ignited by a flame or spark, which may result in an 

explosion.

 Please follow installation instructions carefully. When in doubt, call a 

licensed plumber or your local gas company.

❏  

WARNING: 

DO NOT re-use connectors, fittings and valves;

 they are designed for 

use on original installation only.  Removal of connector and additional handling may  

damage connector making it unsafe for reuse.

❏  

WARNING: 

DO NOT use this connector if it has been in a fire.

 Fire can damage 

the connector making it unsafe for use.

❏  

WARNING: 

DO NOT use this connector on 

appliances equipped with rollers or casters.

 

This connector is designed for limited movement  

after installation.  Repeated bending, flexing or  

extreme vibration can cause metal fatigue. Normal 

vibration and movement of standard household gas 

dryer or similar appliance is okay.

❏  

WARNING: 

DO NOT use connectors to make a 

direct connection to LP gas containers.

   Connection 

MUST be made to the regulator device only.

❏  

WARNING: 

DO NOT use connector on appliances 

in moving vehicles

 such as RV’s, trailers, etc. 

However, this product may be used in manufactured 

housing (permanent residence mobile homes).

ProCoat

®

 

COATED STAINLESS STEEL GAS CONNECTORS  
SELECTION & INSTALLATION INSTRUCTIONS 

For Residential and Commercial Gas Appliances

❏  

WARNING: 

DO NOT use this connector with 

infrared radiant tube heaters.

 Cyclic movement of 

heater may cause connector to fail.

❏  

WARNING: 

Keep cleaning solvents containing  

ammonia or chlorine away from an uncoated 

or  damaged gas connector.

 DO NOT store these 

solutions near connector or use the connector near a 

swimming pool or hot tub. Water rinse the connector 

thoroughly if exposed to these chemical products.

❏  

WARNING: 

DO NOT join this connector to another connector.

 

WARNING: 

DO NOT stretch connector to make it fit

. Connector must be at least 

2 to 3 inches longer than the distance from the gas supply line to appliance when 

pulled out from the supply at its maximum length. 

  

  WARNING:

 

Connector is for use in accessible locations only.

 DO NOT conceal  

  connector or run connector through  enclosed outdoor BBQ pits, walls, partitions,    

  floors or appliance panels.

❏ 

WARNING: 

DO NOT connect gas connector nuts directly to pipe threads

 of gas 

supply pipe or appliance. Install connector using the fittings provided. (see Figure A)

 

CODES AND REGULATIONS

Gas appliance and connector installation MUST conform with all local codes and 

regulations including municipal and state building codes, and to all local utility 

regulations. In the absence of local code, the installation must conform with the 

National Fuel Gas Code ANSI Z223.1/ NFPA No. 54, Uniform Plumbing Code, or 

International Fuel Gas Code. Contact your local gas company for details.

 

INSTALLATION INSTRUCTIONS:

  WARNING:

  Turn off gas supply before disconnecting old appliance. In absence of  

  manual shut-off valve near appliance location, gas MUST be shut off at main valve,  

  near meter.
 

NOTE:

 Fuel gas codes require installation of a manual shut-off valve in the same    

  room, within easy reach of the appliance (i.e. within 6 feet).
1.  Clean all pipe threads with a wire brush and rag to ensure connections are free  

  of  any debris such as metal shavings, rust, dirt, oil or water.
2.  Apply pipe thread sealant to the male pipe threads  

  of connection. DO NOT apply sealant or tape to flare  

  ends of fittings or shut-off valve. Sealant and tape  

  will prevent this connection from sealing properly.
3.  If necessary, thread new manual shut-off valve onto  

  gas supply pipe, wrench tighten.
4.  Thread steel fitting to manual shut-off valve and  

  other steel fitting onto appliance  regulator. 
5.  Thread flare nuts of gas connector onto shut-off valve and steel fitting. Wrench    

  tighten all connections.

TO METER

Figure A

TO APPLIANCE

Отзывы: