6-6
100-214-281 Rev. 07
Chapter 6: Operation
Operating the Actuator
If you do not obtain optimal results initially, based on the quality of the weld obtained and the
loading meter reading, you can alter settings to achieve satisfactory results. Change one setting
at a time until a weld is produced in minimum time with maximum strength.
4
With a part in place, depress and hold both start switches simultaneously, or activate the
start mechanism.
5
The horn advances and contacts the part.
6
Force develops between the horn and the part, activating the load cell.
7
Ultrasonic vibrations are activated. The power bar graph on the power supply indicates
loading (usually in the 25% to 100% range). The start switches can now be released.
8
Ultrasonics stop and the horn continues to clamp the part for the hold time you selected.
9
After the completion of the hold cycle, the horn retracts automatically and you can
remove the part from the fixture.
10
Weld a few parts using the initial parameters and check for the desired properties.
Step:
Action:
Содержание 2000X ao