100-214-281 Rev. 07
4-17
2000X ao Actuator
Chapter 4: Installation and Setup
Instruction Manual
Installation Steps
Figure 4.7
Base Mounting Centers
4.5.2 Mounting the Stand (Actuator on Hub-mounted column)
During unpacking, you removed the hub from the column/stand assembly. You must choose a mounting
location for the hub that will support the column and actuator, and provide the hardware to mount it. Four
mounting bolt holes are provided at the corners of the casting, and will accept your 3/8 inch or M10 hard-
ware. Use flat washers against the metal casting to prevent gouging.
CAUTION
!
The hub must be installed with its front in the same direction as the front of the actuator. The
column bolts of the hub are found on the rear of the hub. See
Bolt Pattern for the Hub (for Stand on Hub),
on page 4-18 for mounting details.
21.31 in / 541 mm
Mounting Holes
accept 3/8 inch
or metric M10
cap screws
75 in /
5 mm
7.37 in /
187 mm
16.5 i
419 m
M10
M
28.0 in / 711 mm