Chapter 2: Introduction to the 2000X ao Actuator
Glossary of Terms
Step @ Ext Sig:
Allows you to shift either force or amplitude based upon an external signal.
Step @ Force:
User-definable point at which AmpA is changed to AmpB.
Step @ Power:
User-definable point at which AmpA or ForceA is changed to AmpBor ForceB.
Step @ Time:
User-definable point at which AmpA or ForceA is changed to AmpBor ForceB.
Suspect Limits:
User-definable limits at which the resultant weld in a welding cycle is identi-
fied as potentially bad (suspect).
Test Scale:
The magnification of the power bar on the front panel of the Power Supply, useful
for lower-power applications that want a more accurate (but smaller) scale.
Time Mode:
Terminates the ultrasonics at a user-specified time.
Timeout:
A time at which the ultrasonic energy terminates if the main control parameter has not
been reached.
Trigger Beeper:
An audible signal sounded when the trigger force has been met, and the trigger
switch is made.
T
rig Delay:
Trigger Delay. A user-programmable time delay between engagement of the trigger
switch and start of ultrasonics and ramping of force to the weld force.
UPS:
Universal Power Supply.
User-defined Limits:
for process resultants, where - is the user-defined lower limit, and + is the
user defined upper limit:
-/+ S/R Energy: The energy reached during the weld.
-/+ S/R Freq: The peak frequency reached during a weld.
-/+ Max Force: The peak force reached during the weld.
-/+ S/R Power: The peak power as a percentage of the maximum reached during the weld.
-/+ S/R Abs D: The absolute distance reached during the weld from the Upper Limit
Switch.
-/+ S/R Col D: The collapse distance reached from trigger to end of weld.
-/+ S/R Trg D: The distance at which the trigger occurred.
-/+ S/R Time: The weld time reached during the weld.
Weld Count:
Count of acceptable weld cycles.
Weld Energy:
The energy specified to be applied to the part during the weld cycle.
Weld History:
The last 50 weld summary data lines are saved.
Weld Scale:
The power bar LED scale during weld.
Weld State:
A screen message showing the current state of the welder during or before the pro-
cess. The list of messages are shown in the Run Screen section.
Weld Results:
A one-line summary of information concerning the last weld cycle.
Weld Time:
The time for which ultrasonics are on.
Содержание 2000X ao
Страница 2: ......
Страница 8: ...iv 100 214 281 Rev 07 ...
Страница 10: ...vi 100 214 281 Rev 07 ...
Страница 12: ...viii 100 214 281 Rev 07 ...
Страница 44: ...3 4 100 214 281 Rev 07 Chapter 3 Delivery and Handling Returning Equipment ...
Страница 84: ...4 40 100 214 281 Rev 07 Chapter 4 Installation and Setup Still Need Help ...
Страница 90: ...5 6 100 214 281 Rev 07 Chapter 5 Technical Specifications Physical Description ...