100-214-281 Rev. 07
2-13
2000X ao Actuator
Chapter 2: Introduction to the 2000X ao Actuator
Instruction Manual
Glossary of Terms
Post Weld Seek:
Used to determine the operating frequency of the Stack, after the Hold and/or
Afterburst portion of the weld cycle. Ultrasonics are run at a low level (5%) amplitude during
this step, and the frequency is stored to memory.
Power Graph:
A printed graph of power in percentage of maximum plotted against time.
Preset:
A method of saving the power supply’s user-set parameters to memory, for a given
Setup. The Power Supply model may allow multiple presets for easy recall of a Setup’s param-
eters, for a given part, process or operation. Presets can be labeled by the user or the system.
Preset Name:
The ability to name a preset in customer-defined terms. Not available in the
2000Xt Power Supply.
Pretrigger:
The setting that causes ultrasonics to start before contact with the part (or, before
the set Trigger Force has been met).
Pretrig Amp:
Pretrigger Amplitude. The amplitude at the horn face during pretrigger.
Pretrg At:
Pretrigger at (a given distance). The distance at which pretrigger is turned on.
Print on Alarm:
Allows the user to set up printing automatically when an alarm occurs.
Print on Sample:
Allows the user to set up printing automatically based on the number of cycles
performed.
Ready Position:
State in which the welder is retracted to the home position and ready to receive
the start signal, ready to operate.
Recall Preset:
Allows a user to activate a preset from memory for purposes of operation or mod-
ification.
Reject Limits:
User-definable limits at which the violating cycle is identified as having pro-
duced a bad part.
Required:
State used with limits indicating that a reset will be required when the limit is
exceeded. The reset is accomplished by using the reset key on the front of the Power Supply.
Reset Required:
State used with limits indicating that a reset will be required when the limit is
exceeded. The reset is accomplished by using the reset key on the front of the Power Supply.
Run Dry Cycle:
A cycle without ultrasonics. Used for diagnostic purposes.
Run Screen:
The screen showing weld status, alarms, weld count, and process information.
Available using a front-panel button on the Power Supply.
Save Preset:
Stores a programmed set of weld parameters as a Preset.
Scrub Time:
In Ground Detect mode, the amount of time after detection of a ground condition
before the termination of ultrasonics, and end of the cycle.
Seek:
The activation of ultrasonics at a low-level (5%) amplitude, for the purpose of finding the
resonant frequency of the Stack.
Sequence:
Allows the sequencing of presets within the welder so that multiple weld points can
be performed with one welding Power Supply and Actuator.
Serial Port:
A RS232 port provided to you for external data communications.
Step @ Energy:
User-definable point at which AmpAor ForceA is changed to AmpB or ForceB.
Содержание 2000X ao
Страница 2: ......
Страница 8: ...iv 100 214 281 Rev 07 ...
Страница 10: ...vi 100 214 281 Rev 07 ...
Страница 12: ...viii 100 214 281 Rev 07 ...
Страница 44: ...3 4 100 214 281 Rev 07 Chapter 3 Delivery and Handling Returning Equipment ...
Страница 84: ...4 40 100 214 281 Rev 07 Chapter 4 Installation and Setup Still Need Help ...
Страница 90: ...5 6 100 214 281 Rev 07 Chapter 5 Technical Specifications Physical Description ...