2000X ao Actuator
Chapter 6: Operation
Instruction Manual
Operating the Actuator
NOTE
i
i
Due to Dynamic Follow Through, do not weld in the last 1/4" of stroke.
6.2.7 Emergency Stop
The Emergency Stop is a user control that will prevent the actuator from running, and will also
immediately terminate a weld cycle and cause the Horn to retract. It does not remove power from
the system. The controls can be configured to provide a beep sound when the emergency stop is
engaged. The front panel display of the power supply will indicate that the system is in emer-
gency stop mode when it is. Twist the emergency stop button to reset the system.
6.3 Operating the Actuator
For detailed information about 2000X ao Actuator controls, refer to
To operate the X ao actuator:
4
When you have reached the setting you want, tighten the lock ring. The
lock ring will prevent the mechanical stop adjustment from vibrating loose
during operation.
5
Place a part in the fixture, reset the air pressure, and perform a test weld.
6
Check that full force develops between the horn and the part. If not, read-
just the mechanical stop.
Step:
Action:
1
If your application has been analyzed in the Branson Applications Laboratory, consult the
Branson Lab Report for appropriate settings or check your 2000X Power Supply manual.
2
Properly adjust the mechanical stop so that the horn does not make contact with your
fixture. (Refer to
for more information on this adjust-
ment.)
3
If the Actuator is mounted on a Base, make sure that the Emergency Stop button is not
pushed in.
If not using the Branson Base, verify that the Emergency Stop signal source is not in the
Emergency Stop mode.
Содержание 2000X ao
Страница 2: ......
Страница 8: ...iv 100 214 281 Rev 07 ...
Страница 10: ...vi 100 214 281 Rev 07 ...
Страница 12: ...viii 100 214 281 Rev 07 ...
Страница 44: ...3 4 100 214 281 Rev 07 Chapter 3 Delivery and Handling Returning Equipment ...
Страница 84: ...4 40 100 214 281 Rev 07 Chapter 4 Installation and Setup Still Need Help ...
Страница 90: ...5 6 100 214 281 Rev 07 Chapter 5 Technical Specifications Physical Description ...