100-214-281 Rev. 07
2-7
2000X ao Actuator
Chapter 2: Introduction to the 2000X ao Actuator
Instruction Manual
Controls and Indicators
2.4 Controls and Indicators
The Actuator Controls for the 2000X ao Actuator are found in two locations: on the Actuator or
on the Remote Pneumatics Box. The 2000X rp is a separate component of a 2000X ao. System
controls and Actuator power are provided by the 2000X-series Power Supply.
•
Stroke Indicator
Provides a quick method of determining relative carriage travel during an
operating cycle. A scale is provided to indicate relative distance.
NOTE
i
i
The mechanical stop is not intended for welding by distance.The mechanical stop
is not intended for welding by distance.
The front panel controls on the 2000X ao Actuator are listed below.
•
Pressure Indicator:
Indicates that the actuator is receiving pressurized air.
•
Power Light:
Indicates that the Actuator is connected to the Power Supply and that the
Power Supply’s main power is on.
•
Carriage Door:
Provides access to the converter-booster-horn stack; secured by four M5
hex screws. Use a T-handle wrench to tighten the hex screws.
•
Mechanical Stop:
Limits the stroke length to prevent the horn from contacting the fixture
when no workpiece is in place; adjustment is approximately 0.04 in. (1 mm) per rotation; a
locking ring keeps the setting from vibrating loose. Turning the knob clockwise increases the
stroke length.
CAUTION
!
Turning the mechanical stop too far can cause it to come apart.
Controls on the 2000X rp Remote Pneumatics Box are listed below.
•
Pressure Regulator:
Adjust the amount of air pressure applied to the cylinder; range of 5-
100 psig (35-700 kPa). Pull to set; push to lock.
•
Downspeed Control:
Downspeed knob controls the rate of descent and force buildup on the
part to be welded.
• Pilot Light:
Indicates that the actuator is connected to the power supply, that the 2000X rp
remote box is electrically connected to the 2000ao actuator, and that the power supply’s main
power is on.
• Pressure Gauge:
Indicates the amount of air pressure applied to the cylinder; range of 5-
100psig (35-700 kPa). Pull to set; push to lock.
Содержание 2000X ao
Страница 2: ......
Страница 8: ...iv 100 214 281 Rev 07 ...
Страница 10: ...vi 100 214 281 Rev 07 ...
Страница 12: ...viii 100 214 281 Rev 07 ...
Страница 44: ...3 4 100 214 281 Rev 07 Chapter 3 Delivery and Handling Returning Equipment ...
Страница 84: ...4 40 100 214 281 Rev 07 Chapter 4 Installation and Setup Still Need Help ...
Страница 90: ...5 6 100 214 281 Rev 07 Chapter 5 Technical Specifications Physical Description ...