1

 

MANUAL P/N 900000106 REV A 

 

 
 
 
 
 
 

User Guide 

 

Frequency and Time Synthesizer Unit 

 

Model FTSU-100D 

 

P/N 001-0187 

 

 

 

Revision A 

 

March 2010 

 
 
 
 
 
 
 
 

 

Brandywine Communications 

1153 Warner Ave. 

Tustin, CA 92780 

(714) 755 1050 
(714) 755 0175 

 

http://www.brandywinecomm.com

 

 
 
 
 

Содержание 001-0187

Страница 1: ...106 REV A User Guide Frequency and Time Synthesizer Unit Model FTSU 100D P N 001 0187 Revision A March 2010 Brandywine Communications 1153 Warner Ave Tustin CA 92780 714 755 1050 714 755 0175 http www...

Страница 2: ...2 MANUAL P N 900000106 REV A Revision History REVISION DATE COMMENTS A 03 29 2010 Initial Release...

Страница 3: ...equilateral triangle is intended to alert the user to the presence of un insulated dangerous voltage within the product s enclosure The dangerous voltage may be of sufficient magnitude to constitute a...

Страница 4: ...4 MANUAL P N 900000106 REV A This page intentionally left blank...

Страница 5: ...Installation 10 3 1 Unpacking 10 3 2 Installation 10 3 3 Connections 11 3 3 1 Power 11 3 3 2 Other Connections 11 4 Getting Started 12 4 1 Powering Up the FTSU 100D 12 4 2 Setting the Network Address...

Страница 6: ...ble Accuracy 5x10 12 24 hour average Short term stability Allan variance 2x10 11 1 s 4x10 11 10 s 8x10 11 100 s Phase noise 120 dBc Hz 10 Hz 140 dBc Hz 100 Hz 150 dBc Hz 1000 Hz Harmonic distortion 30...

Страница 7: ...erence Available PLL and or reference PLL Locked Holdover Fault Red Indicates monitored parameter is out of range 1 5 Environmental Temperature Unit Operating 0 50 C Storage 40 to 85 C Humidity Unit 1...

Страница 8: ...tputs SHIELD GND J17 J18 J19 J20 J21 J22 J23 J24 QMA CENTER 1PPS Outputs SHIELD GND J25 J26 QMA CENTER 1PPS Inputs SHIELD GND J27 J28 QMA CENTER 10 MHz Reference inputs SHIELD GND STATUS INPUT OUTPUT...

Страница 9: ...s from the reference generator The FTSU 100D provides automatic changeover should one of the source inputs fail Manual source select override is available on the front panel A variety of status indica...

Страница 10: ...INCORRECT AC LINE SETTING IS USED WARNING REMOVE THE POWER CORD FROM THE FTSU 100D BEFORE ADJUSTING THE LINE VOLTAGE If the AC line setting is incorrect detach the power cord from the power entry modu...

Страница 11: ...eference signals to the appropriate connectors on the rear panel CAUTION FOR CORRECT OPERATION REFERENCE FREQUENCY A AND REFERENCE FREQUENCY B MUST BE THE SAME FREQUENCY WHICH IS TYPICALLY 10 MHz Conn...

Страница 12: ...ls it will be automatically switched to Reference B Place the Source Select Switch in the PLL position This is the normal mode of operation for the FTSU 100D and this indicates that the reference freq...

Страница 13: ...unit click the button 7 Wait 15 seconds for the settings to be loaded into the FTSU 100D unit and for the FTSU 100D unit to restart 8 Verify that the FTSU 100D unit has the correct network settings a...

Страница 14: ...other end of the Ethernet cable to your network 3 Open a web browser type the IP Address of the FTSU 100D unit in the Address bar and press Enter For example type 192 168 1 1 or http 192 168 1 1 and p...

Страница 15: ...ads link 3 Click on the Java Download link 4 Download Java 5 Complete the installation process Please note that the oldest acceptable Java software version number is 1 4 2_05 To check the Java softwar...

Страница 16: ...tem The System tab consists of the System Status This tab allows the user to view the state and status of the FTSU 100D system Figure 3 FTSU 100D System Screen The System Status section consists of te...

Страница 17: ...All values changed are written to non volatile memory To undo all modifications made to the Setup screen click the Reset button This loads the system defaults Figure 4 Setup Screen 5 1 2 1 System The...

Страница 18: ...s the user to define sub networks The Device Gateway is a 32 bit number used as the point of entrance from one network to another Please note that once the IP address is changed using the web browser...

Страница 19: ...n click the Reset button IMPORTANT INFORMATION The default user name and password for the system is BRANDYWINE The user must always enter a user name and password when submitting changes to the system...

Страница 20: ...MANUAL P N 900000106 REV A 20 5 1 4 Alarm The Alarm tab consists of the Index and the Fault Detected sections Figure 6 Alarm Screen...

Страница 21: ...MANUAL P N 900000106 REV A 21 5 1 5 1 PPS The 1 PPS tab consists of three sections the 1PPS Output Width 1PPS Delay and 50 ohm Load Figure 7 1PPS...

Страница 22: ...7 nanoseconds would be entered as 327 Likewise to advance a 1PPS output signal enter a positive value in the appropriate box To advance a 1PPS signal by 85 nanoseconds a value of 85 should be entered...

Страница 23: ...ab consists of the Output Setup for the 10MHz and 70MHz outputs To save all modifications made to each output click the button Figure 8 Output Each high frequency output has three adjustable settings...

Страница 24: ...allow the user to set low and high alarm thresholds to each output signal If these values are exceeded an alarm will result 5 1 7 Serial The Serial Settings tab sets the Serial Port Configuration This...

Страница 25: ...ilities listed below FTSU 100D status monitoring via SNMP FTSU 100D control via SNMP Figure 10 is displayed when the SNMP sub tab is selected The SNMP consists of three sections the Community Trap Add...

Страница 26: ...sists of one field the Trap IP The Trap Address allows the user to enter the IP address of the trap Once the trap address is entered it is stored in non volatile memory and will be recalled when the F...

Страница 27: ...the system Help links are located throughout the entire system so the user has access to the Help screen whenever the user encounters a problem Once the user clicks on the Help link the user will be a...

Страница 28: ...Update program from the NetBurner website located at http www netburner com support public_downloads html 1 Double click on the AutoUpdate icon and Figure 12 will be displayed Figure 12 AutoUpdate Scr...

Страница 29: ...le Name field will be completed for you Figure 14 Open Screen 4 Now click on the Reboot when complete check box 5 To close the application click the Dismiss button 6 To upload the new firmware click t...

Страница 30: ...MANUAL P N 900000106 REV A 30 Figure 16 AutoUpdate Complete Screen...

Страница 31: ...e output signals is outside its allowable threshold values 2 One or both of the input signal sets are faulty 3 PLL is not locked 1 Check alarm screen to verify cause of fault 2 Check alarm screen to v...

Страница 32: ...MANUAL P N 900000106 REV A 32 8 Drawings FIGURE DESCRIPTION 1 FTSU 100D Front Panel 2 FTSU 100D Rear Panel Table 21 FTSU 100D Drawings...

Страница 33: ...MANUAL P N 900000106 REV A 33 Figure 1 FTSU 100D Front Panel Figure 2 FTSU 100D Rear Panel...