The power cable (H05 RR-F, H05 RN-F or H05 VV-F) must be of sufficient length to be connect-
ed to the build-in oven while it sits on the floor in front of the cabinet.
To do this the appliance must be disconnected from the electrical network:
—
Open the inspection flap located at the lower right of the back cover by unscrewing the two
screws, then pivot the inspection flap.
—
Strip 12 mm along each wire of the new power cable.
—
Carefully twist together the strands.
—
Loosen the screws from the terminal board and remove the power cord to be replaced.
• Introduce the power cable through the side of the cover in the cable clip located to the right of
the terminal board.
—
All the strands of the electricity wires must be captured under the screws.
— The phase wire on the L terminal.
— The green-yellow coloured earth wire should be connected to the terminal
.
—
The neutral conductor (blue) on the N terminal.
—
Screw down tightly the screws on the terminal board and check the connection by pulling on each
wire.
—
Attach the cable with the cable clip located to the right of the terminal board.
—
Close the inspection flap using the two screws.
Warning
We cannot be held responsible for any accident resulting from inexistent, defective or
incorrect earthing.
If the electrical installation in your residence requires any changes in order to hook up your
appliance, call upon a professional electrician.
If the oven malfunctions in any way, unplug the appliance or remove the fuse corresponding
to the sector where the oven is hooked up.
CHANGING THE POWER CABLE
2 / INSTALLING YOUR APPLIANCE
EN
99638345_A_ML.qxp 16/01/2007 10:53 Page 52