GB
75
l l y o u r o v e n
We cannot accept any liability in the event of an accident
resulting from non-existent or faulty earthing.
• The supply cable (H05 RR-F, H05 RN-F or H05 W-F) must be long enough to allow
the oven to rest on the floor in front of its housing.
With the oven sitting on the floor and disconnected:
• Open the trapdoor at the bottom right hand side at the back of the oven by
removing the 2 screws and swinging the door away.
• Remove the sheath from each wire in the new cable up to 12 mm.
• Twist the ends carefully together.
• Unscrew the terminal screws and remove the wires that need changing.
• Pass the new cable through the wire clamp to the right of the terminals.
• Connect the wires up in accordance with the markings on the terminals.
• Make sure all wires are trapped under the screws.
• The brown wire (live) going to terminal marked L.
• The green and yellow wire (earth) going to the one marked
.
• The blue wire (neutral) going to the terminal marked N.
• Tighten the screws and check, by tugging on each wire, that they are firmly connected.
• Tighten the clamp to hold the cable.
• Close the trapdoor using the two screws.
F
itting new wiring and/or changing cables.
The electrical connections are made before the oven is installed in its housing.
• The oven must be connected using an approved 3-core cable (live, neutral and
earth
) with 1.5 mm square conductors. This should be connected via a 3- pin-
socket (live, neutral, and earth
to the main supply which should be should be a
220-240V, alternating single-phase current. If the oven is not connected using a
plug and socket, it must be connected to a multi-pole switch with a minimum gap
of 3 mm between contacts. The earth wire (green and yellow) should be connected
to the terminal marked with the earth symbol
on the appliance and to the earth
in the switch.
• Where the oven is connected using a separate plug and socket this must be
accessible after the oven has been installed.
• The neutral wire (blue) of the oven must be connected to the neutral in the main supply.
99625462.qxd 14/10/02 11:17 Page 75
Содержание FC 224
Страница 4: ...4 O v e r s i g t o 1 3 5 T c 1 2 3 4 5 6 99625462 qxd 14 10 02 11 14 Page 4...
Страница 10: ...10 I n s t a l l a t i o M l til indbygning af ovnen 99625462 qxd 14 10 02 11 15 Page 10...
Страница 26: ...26 H u r s e r u 1 3 5 T c 1 2 3 4 5 6 99625462 qxd 14 10 02 11 15 Page 26...
Страница 32: ...32 H u r s k a u g n e n Nyttiga m tt f r att bygga in ugnen 99625462 qxd 14 10 02 11 15 Page 32...
Страница 48: ...48 P r e s e n t a s j o n 1 3 5 T c 1 2 3 4 5 6 99625462 qxd 14 10 02 11 16 Page 48...
Страница 70: ...70 Y o u r 1 3 5 T c 1 2 3 4 5 6 99625462 qxd 14 10 02 11 17 Page 70...
Страница 76: ...76 H o w t o i n s t a l l y o u r Dimensions for installation use 99625462 qxd 14 10 02 11 17 Page 76...
Страница 90: ...99625462 qxd 14 10 02 11 17 Page 90...
Страница 91: ...99625462 qxd 14 10 02 11 17 Page 91...
Страница 92: ...99625462 10 02 99625462 qxd 14 10 02 11 17 Page 92...