System User Guide Rev. 1.6, Planning & Transfer Systems
59
IPLAN NET SERVER
4.5.6
System Insight Display LEDs and Health LED Combinations
Introduction
When the health LED on the front panel illuminates either amber or red, the server is experiencing
a health event (processor failure, PPM failure and DIMM).
Combinations of illuminated system LEDs, system power LED and the internal health LED indicate
the system status.
LED Indications
Regarding Failures
NOTE: In the event of failure indications, contact Brainlab support.
Systems insight
display LED
Health
LED
System
power
LED
Status
Processor failure,
socket X,
amber
Red
Amber
One or more of following conditions may exist:
• Processor in socket X has failed
• Processor X is not installed in the socket
• Processor X is unsupported
• ROM detects a failed processor during
POST
Amber
Green
Processor in socket X is in a pre-failure condi-
tion
DIMM failure, slot
X,
amber
Red
DIMM in slot X has failed
Amber
DIMM in slot X is in a pre-failure condition
Содержание IPLAN NET SERVER
Страница 2: ......
Страница 6: ...6 System User Guide Rev 1 6 Planning Transfer Systems...
Страница 20: ...20 System User Guide Rev 1 6 Planning Transfer Systems Correct Handling...
Страница 68: ...68 System User Guide Rev 1 6 Planning Transfer Systems Turning System On Off...
Страница 82: ...82 System User Guide Rev 1 6 Planning Transfer Systems Compliances iPlan Net Server...
Страница 88: ...88 System User Guide Rev 1 6 Planning Transfer Systems iPlan Workstations iPlan Net Server...
Страница 91: ......
Страница 92: ...brainlab com Art No 60908 91EN 60908 91EN...