background image

SPEEDSWITCH M800

UNDERSPEED MONITOR

UNDERSPEED MONITOR - PART Nos. 220V ac M8001V2A

UNDERSPEED MONITOR - PART NO.

 110V ac M8001V1A

UNDERSPEED MONITOR - PART NO.

 24V dc M8001V4A

TECHNICAL INFORMATION

INSTALLATION
INSTRUCTIONS

M2534A                                                                                                                                                                                           >:M800EliteA-Cat3-Man

BASIC FAULT FINDING

1)

Input light does not illuminate.
Check that you have a supply of the correct value across the brown and blue
wires. Slide a screwdriver blade across the face of the sensor, the input light
should flicker. If not, contact your supplier. If it does, move the front face nearer
the target and check target size is as specified under "Installation".

2)

Input light stays on permanently.
Either increase the gap between the target and the shaft, or between the
target and the sensor face.

GUARANTEE

The equipment is covered by a 12 months guarantee from the date of shipment.  Any faults
arising due to faulty materials or workmanship, within the guarantee period, will be corrected
free of charge providing the equipment is returned to us carriage paid.

BRAIME ELEVATOR
COMPONENTS LTD.

Hunslet Road, Leeds,
England. LS10 1JZ
Tel: +44 (0) 113 246 1800
Fax: +44 (0) 113 243 5021
e-mail: [email protected]
Web: www.braime.com

SETEM

2 Route de Corbie
80800 Lamotte Warfusée
France
Telephone: 03 22 42 32 26
Fax: 03 22 42 37 33
e-mail: [email protected]
Web: www.braime.com/setem

II 

3D T100°C Tamb -15°C to + 50°C IP65

Supply

110V ac or 220V ac 50/60 Hz or 24V ac/dc (specify when ordering).

Fusing

Unit should be wired to a supply rated at 5A  maximum.

Speed Range

10-3600 PPM. (Pulses Per Minute).

Operating Range

9mm max. (ferrous) 6mm max. (non-ferrous)

Target

Ideally ferrous min. 20mm dia.  Accessory M500 TG Target Disc
Available.

Start up Delay

User Selectable 0-30 Seconds

Calibration

Unit is automatically calibrated by the application of a magnet. (Applied
to CAL point on label when shaft is running at speed).

Repeat Accuracy

Better than 2%

Enclosure

Moulded PC/ABS.

Protection

IP67 dust & water tight.

Trip Point

Using Single Set Point either 10% or 20% underspeed.  Using Dual
Set Points both 10% and 20% underspeed.

Output Relay

First Relay Normally Open.  Contact Closes at 10% speed. Second
Relay Normally Closed.  Opens at -20% speed.  Rated 2.5A 240V AC.

LED Display

RED LED indicates input pulses. GREEN LED shows output at nominal
speed and acts as calibration aid. It may flicker during normal operation.

Weight

185 grams.

Tacho Output

Opto-isolated output provided, rated at 30V dc 100mA max, fully
protected. To feed tachos and other electronic equipment.

Отзывы: