4.6
Service/diagnostic menu
Main Menu - Warning - Service/diagnostic
When entering this menu choice, a warning window will appear.
The purpose of this warning is make the user aware that the safety
switches on the cover are now disabled. This is done to make it possi-
ble to run smaller tests during service.
Please be aware of rotating parts to prevent injuries!
The printer may be unexpectedly started by other users!
Print demo text:
Main Menu - Warning - Service/diagnostic - Warning - Print demo text
Prints a short demo text on approx. one sheet of paper.
Print Test Pattern:
Main Menu - Warning - Service/diagnostic - Warning -
Print Test Pattern
When entering this menu choice, a warning window will appear.
This is to make the user aware that print jobs from the computer will
not be printed as long as you are in this sub-menu.
- X pattern.
Will print dots in a x pattern across the sheet,
useful when searching for missing dots.
- Full cell, single sided.
Prints all six dots on all characters on one side of the sheet,
useful for dot quality tests.
- Full cell, both sides.
Prints all six dots on all characters on both sides of the sheet,
useful for testing the paper quality.
- O/Ø pattern.
Prints a test pattern made of dot 1,3,5 and 2,4,6, single-sided, useful
when searching for extra dots.