Arrhythmia Event Monitor 

 

 

 

Caution:  U.S. Federal law restricts this device to 

sale by or on the order of a physician

 
 

 

Содержание ER910

Страница 1: ...10 ER910 ER910 ER910 920 920 920 920 And And And And ER910 ER910 ER910 ER910 920 920 920 920 AF AF AF AF Arrhythmia Event Monitor Caution U S Federal law restricts this device to sale by or on the order of a physician ...

Страница 2: ...t for the express warranties stated above Braemar disclaims all warranties including implied warranties of merchantability and fitness The stated express warranties are in lieu of all obligations of liabilities on the part of Braemar for damages including but not limited to special indirect or consequential arising out of or in connection with the use or performance of Braemar products Any action ...

Страница 3: ...n The ER910 920 Event Monitors are enhanced with Arrhythmia Detection firmware which will capture and automatically record asymptomatic infrequent or elusive heart arrhythmia events such as Bradycardia Tachycardia and Pause The ER910 920 AF includes all of these features and in addition Atrial Fibrillation Once an event is recorded patients may transmit their ECG transtelephonically Indications fo...

Страница 4: ...s 3 Connect Patient Cable to Monitor Electrode Application and Placement For each electrode lead wire 1 Snap the electrode onto the lead wire 2 Remove the protective backing from the adhesive side of the electrode 3 Apply the electrode to the patient s skin per Electrode Placement diagram in this manual or as instructed by the physician Notes A You must use a Patient Cable that the Monitor is able...

Страница 5: ... it is connected to the Monitor Open the battery compartment by sliding battery door downward Install two fresh AAA Alkaline batteries Observe proper battery polarity The Monitor will sound rising tones after completion of power up After a few seconds the display will show the battery level and number of events stored The battery level should be near 100 The number of events stored does not matter...

Страница 6: ...y sophisticated there is no guarantee that the device will catch all episodes of arrhythmia For maximum efficacy use the most sensitive settings ER910 920 and ER910 920 AF Event Monitor 8 Notes about sound A Lead loss sound overrides the POST EVENT SOUND setting B If the Monitor has lead loss during a recording the Monitor will produce an audible sound of the event until the recording is complete ...

Страница 7: ...c POST EVENT TIME Default 30 sec Seconds of ECG data stored after event activation time minimum of 5 sec OF EVENTS Default 5 Total number of events the Monitor will store The maximum number allowed is dependent on Pre and Post Event times Continue on next page ER910 920 and ER910 920 AF Event Monitor 10 User Defined options continued Display Option Description POST EVENT SOUND Default ON ON Sound ...

Страница 8: ...r will display STOPPED in the upper left C Inserting the Patient Cable at this time will erase all events and restart the Monitor ER910 920 and ER910 920 AF Event Monitor 12 5 Connect the patient A At this time the patient leads should be connected to the electrodes and the electrodes should be connected to the patient B Insert the Patient Cable into the Monitor Notes If the patient is connected c...

Страница 9: ...ECORD SEND button for two seconds until an audible tone is heard then release Notes A There are two RECORD SEND buttons you only need to push one of them for two seconds to activate the Monitor B To stop a recording press the RECORD SEND button again for two seconds C RECORDING will flash in the upper left hand corner of the display 2 Hold as still as possible during recording but continue breathi...

Страница 10: ...be able to access the AUDIO setting While monitoring press and hold only one of the programming buttons for two seconds to access the AUDIO setting Cannot access AUDIO setting Patient wants to mute Monitor AUDIO setting cannot be accessed during a recording Wait until end of recording then access AUDIO screen No phone ring at end of recording The AUDIO setting is turned on which mutes most sounds ...

Страница 11: ...Patient Cable Pulling on lead wires may damage cable Verify the recording did not take place near a source of electromagnetic interference fluorescent lights computer monitors or household appliances Noise artifact on recorded ECG at patient location Move electrodes slightly to the right or left of the original location All or groups of timestamps for recordings are the same If the inadvertent los...

Страница 12: ...ction or maintenance that can be performed by the end user Service Items and Accessories Description Part Number Patient lead 1 channel shielded 350 0173 09 Patient lead 2 channel shielded 350 0173 10 Monitor belt clip Holster 100 1764 002 Necklace 350 0180 00 Operator manual 600 0606 00 AAA I E C LR03 Alkaline Battery 200 2492 001 ER910 920 and ER910 920 AF Event Monitor 20 Equipment Symbols Symb...

Страница 13: ...e One channel 30 minutes Two channel 30 minutes Max total record time One channel 30 minutes Two channel 30 minutes Type Flash Data retention Non volatile Physical Dimensions 3 5 x 2 125 x 65 89 9mm x 54 0mm x 15 7mm Weight with batteries 3 5 oz Enclosure Molded plastic Operating position Any orientation Electrical Input impedance 2M min CMR ratio 60dB AC signal range 3mV DC signal range 300mV Res...

Страница 14: ...to the public low voltage power supply network that supplies buildings used for domestic purposes Electromagnetic Immunity Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relat...

Страница 15: ... equipment Separation distance according to frequency of transmitter Rated maximum output power of transmitter W 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be esti...

Страница 16: ...Braemar Inc Phone 800 328 2719 1285 Corporate Center Drive Suite 150 Fax 651 286 8630 Eagan MN 55121 USA E Mail Service BraemarInc com Copyright 2006 Braemar Inc All rights reserved ...